期刊文献+

A multiscale model for analyzing the synergy of CS and WSS on the endothelium in straight arteries 被引量:5

A multiscale model for analyzing the synergy of CS and WSS on the endothelium in straight arteries
下载PDF
导出
摘要 A multiscale model was proposed to calculate the circumferential stress (CS) and wall shear stress (WSS) and analyze the effects of global and local factors on the CS, WSS and their synergy on the arterial endothelium in large straight arteries. A parameter pair [Zs, SPA] (defined as the ratio of CS amplitude to WSS amplitude and the phase angle between CS and WSS for different harmonic components, respectively) was proposed to characterize the synergy of CS and WSS. The results demonstrated that the CS or WSS in the large straight arteries is determined by the global factors, i.e. the preloads and the afterloads, and the local factors, i.e. the local mechanical properties and the zero-stress states of arterial walls, whereas the Zs and SPA are primarily determined by the local factors and the afterloads. Because the arterial input impedance has been shown to reflect the physiological and pathological states of whole downstream arterial beds, the stress amplitude ratio Zs and the stress phase difference SPA might be appropriate indices to reflect the influences of the states of whole downstream arterial beds on the local blood flow-dependent phenomena such as angiogenesis, vascular remodeling and atherosgenesis. A multiscale model was proposed to calculate the circumferential stress (CS) and wall shear stress (WSS) and analyze the effects of global and local factors on the CS, WSS and their synergy on the arterial endothelium in large straight arteries. A parameter pair [Zs, SPA] (defined as the ratio of CS amplitude to WSS amplitude and the phase angle between CS and WSS for different harmonic components, respectively) was proposed to characterize the synergy of CS and WSS. The results demonstrated that the CS or WSS in the large straight arteries is determined by the global factors, i.e. the preloads and the afterloads, and the local factors, i.e. the local mechanical properties and the zero-stress states of arterial walls, whereas the Zs and SPA are primarily determined by the local factors and the afterloads. Because the arterial input impedance has been shown to reflect the physiological and pathological states of whole downstream arterial beds, the stress amplitude ratio Zs and the stress phase difference SPA might be appropriate indices to reflect the influences of the states of whole downstream arterial beds on the local blood flow-dependent phenomena such as angiogenesis, vascular remodeling and atherosgenesis.
出处 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2006年第1期76-83,共8页 力学学报(英文版)
基金 The project supported by the National Natural Science Foundation of China (10132020 and 10472027) The English text was polished by Yunming Chen.
关键词 Stress Synergy Endothelium Factor Multiscale model Stress Synergy Endothelium Factor Multiscale model
  • 相关文献

参考文献2

二级参考文献22

  • 1冯元桢.生物力学--活组织的力学特性[M].长沙:湖南科学技术出版社,1986.314-318.
  • 2冯元桢 康振黄 等.创伤中肺水肿的原因.生物力学--运动、流动、应力和生长[M].成都:四川教育出版社,1993.608-614.
  • 3Brands P J, Hoeks APG, Rutten MCM, et al. A noninvasive method to estimate arterial impedance by means of assessment of local diameter change and the local centerline blood flow velocity using ultrasound. Ultrasound in Med & Biol, 1996, 22(7): 895~905.
  • 4Langille BL, O'Donnell F. Reductions in arterial diameter produced by chronic decreases in blood flow are endothelium-dependent. Science, 1986, 231:405~407.
  • 5Langer R, Vacanti JP. Tissue engineering. Science, 1993,260:920~926.
  • 6Kamiya A, Togawa T. Adaptive regulation of wall shear stress to flow change in the canine carotid artery. Am J Physiol (Heart Circ Physiol), 1980, 239:H14~H21.
  • 7Fung YC. Biomechanics. Motion, Flow, Stress, and Growth, New York: Springer-Verlag. 1990.
  • 8Liu SQ. Biomechanical basis of vascular tissue engineering. Critical Reviews in Biomedical Engineering, 1999, 27:75~148.
  • 9Ando J, Kamiya A. Blood flow and vascular endothelial cell function. Frontiers Med Biological Eng, 1993, 5:245~264.
  • 10Markou CP, Ku DN. Accuracy of velocity and shear rate measurements using pulsed Doppler ultrasound: a comparison of signal analysis techniques. Ultrasound in Med & Biol, 1991, 17(8): 803~814.

共引文献17

同被引文献22

引证文献5

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部