摘要
结合工程实例,介绍了解决供热站的循环水泵设计选型扬程高、供热负荷不足,耗能高的方法,阐述了叶轮切削处理以及热网运行调节两项节能措施,从而提高生产运行的经济效益。
Combined with specific engineering, it introduces method on settling high lift、under-loaded heat and high energy-wasting of recycle water pump of heating station, and illustrates energy-saving measures including impeller cutting and operational regulation to improve economic benefit.
出处
《山西建筑》
2006年第5期184-185,共2页
Shanxi Architecture
关键词
换热站
供热管网
循环水量
变频调速装置
heat transfer station, heating pipe, recycle water, frequency control device