摘要 HL-1M是HL-1的改进装置,去掉铜壳后,对极向场线圈和电源都做了必要的修改。此外,还增加了四个快垂直场线圈,并采用可控环流四象限晶闸管交流器供电。对装置调试和运行结果表明.反馈控制系统能很好地维持等离子体平衡。放电一直持续到铁芯变压器的伏秒数用完为止,最长达1040ms。在多数放电的平顶段,等离子体位置都被控制在±4mm之内. The HL-1M is a modification of the HL-1 tokamak. The poloidal field coils and the power supply have been modified after the removal of the copper shell. Besides. four fast vertical field coils have been added, supplied by a four-quadrant thyristor convertor, with the circulating current controlled. The commissioning results and subsequent operation showed that the plasma position was well maintained by the feedback control system with discharge continued until the exhaustion of the volt-seconds of the iron core transformer.The maximum discharge time is 1040ms, and the horizontal and vertical plasma positions can be kept within ±4mm over the plateau of the plasma current.
出处 《核聚变与等离子体物理》 CAS CSCD 北大核心 1996年第3期32-38,共7页 Nuclear Fusion and Plasma Physics
关键词 等离子体平衡 反馈控制 托卡马克 Plasma equilibrium Feedback control
  • 相关文献

参考文献3

二级参考文献3

共引文献2

同被引文献37

  • 1秦运文,王恩耀,严建成,谈满秋,袁保山,董贾福,任俱前,孙守祁,叶高英,邓中朝,冉利波,左鹤年,刘莉,张利,严东海,杨青巍,陈燎原,贺红光,段旭如,姚良骅,崔正英,潘宇东,邓希文.HL-1M装置欧姆等离子体实验的初步分析[J].核聚变与等离子体物理,1997,17(1):18-26. 被引量:3
  • 2冯亚兴 汪占河 等.-[J].核聚变与等离子体物理,1998,18:56-60.
  • 3李贵清.-[J].机械技术动态,1994,(3):1-3.
  • 4HL-1M Team.-[J].核聚变与等离子体物理,1998,18:9-19.
  • 5崔正英 刘莉 等.-[J].核聚变与等离子体物理,1998,18:62-66.
  • 6严东海 王恩耀 等.-[J].核聚变与等离子体物理,1998,18:51-55.
  • 7谈满秋.中国环流器新一号装置总体联调[J].核聚变与等离子体物理,1997,17(2):1-8. 被引量:4
  • 8严东海,孙守祁,许正华,黄永康,刘建宏,张炜,兰亚明.HL-1M装置的真空抽气系统[J].核聚变与等离子体物理,1997,17(2):57-60. 被引量:9
  • 9陆志鸿,姜云霞,杨进蔚,等.HL-1装置等离子体平衡的实验研究[J].核聚变与等离子体物理,1986,6(3):154.
  • 10[4]Schneider F.Novel method of determining the plasma position and its application to the ASDEX feedback system [A].Proceedings of 10th Symposium on Fusion Technology [C].Padova:1978.1013.

引证文献3

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部