摘要
建立采用氢化物发生电感耦合等离子发射光谱(HGdCP-AES),测定纺织品中可萃取痕量汞的方法。通过对ICP—AES工作参数进行优化和选择,方法的检出限为0.11μg/L,最小检出量为0.0022mg/kg;汞含量为20.0μG/L时,相对标准偏差为4.9%;汞含量为5.5μg/L时,相对标准偏差为6.3%(n=8);回收率为93.3%-102.7%。该方法可满足Oeko-Tex标准100对纺织品中可萃取痕量汞的检测要求。
A method for the determination of trace extractable mercury in textiles by HG-ICP-AES has been developed. Operation parameters of ICP-AES were optimized and selected. The detection limit was 0.11 μg/L. The minimum detection quantity was 0, 0022 mg/kg. The RSD was 4.9% at a level of 20.01μg/L and 6.3% for 5.51μg/L( n = 8). The recovery was in the range of 93.3% - 102.7%. This method is applicable to the determination of trace extractable mercury in textiles with Oeko-Tex Standard 100,
出处
《印染》
北大核心
2006年第7期37-39,共3页
China Dyeing and Finishing
关键词
测试
汞
纺织品
testing
mercury
textiles