摘要 研究了负载5-Br-PADAP-苯聚氨酯泡沫塑料富集火焰原子吸收测定钻的方法。实验结果表明,此法在pH为7.16~7.3之间可定量吸附钴,平衡时间约20分钟,吸附量约420μg/g、1000倍的约20种常见离子不干扰测定。检出限为0.04μg/ml,方法简便、快速、灵敏。 The determination of Co using the loaded 5-Br-PADAP-benzenol polyurethane foamred plasties by cnriching flameatomic absorption spcctronctry has been studied.The experiment showed that the method could absorb co quantitively at a pH ofbetween 7,16 and 7.30,the balance time was 20 minutes and the absorptivc capacity was about 420μg/g. The detection limit was 0.04μg/ml,about 20kinds of common ions as l000 times as Co had no interference.The method was simple ,qukick and sensitive.
出处 《微量元素与健康研究》 CAS 1996年第2期47-49,共3页 Studies of Trace Elements and Health
关键词 富集 火焰原子吸收法 泡沫塑料 enriching,flame atomic absorption peetrometry. 5-Br-PADAP-benzenol polyurthane foamed plastics,Cobalt.