摘要 本文用国际电工委员会(IEC)建议的方法对市场上几种常见类型家用微波炉的输出功率、均匀性及安全性进行了更仔细的测定.由我们的工作得出结论:测量微波炉功率时,用2000g水作为负载较为合适,且负载面积应占腔体底面积的16%以上,此时测出的功率更准确和接近标称功率,而测定微波炉漏能时则应使用较小负载.转盘转动时负载的受热均匀性较转盘静止时提高约1倍. The properties of several domestic microwave ovens have been measured in more detail according to the method suggested by IEC. The results show that the output power of an oven can be measured more accurately by using a water load of 2000g. But when measuring the leakages of an oven, it is better to use a load of 500g. The heating uniformity of a load in an oven is improved up to 70-80% when the load is moved on a turntable.
出处 《微波学报》 CSCD 北大核心 1996年第2期159-162,共4页 Journal of Microwaves
关键词 微波炉 功率测量 均匀性 安全性 测定 Microwave oven, Power measurement, Heating uniformity, Leakage
  • 相关文献

参考文献3

  • 1黄养元,真空电子技术,1991年,2卷,182页
  • 2季天仁,第四届全国微波能应用学术会议.下,1989年
  • 3陈承坤,全国微波会议论文集.下,1987年

同被引文献23

  • 1张小峰,蒙林,唐相伟,殷勇.平板微波炉新型3D天线研究[J].真空电子技术,2013,26(2):43-46. 被引量:2
  • 2张磊,李法民,陈喜.天线、烧杯对微波炉加热均匀性影响的研究报告[J].电器,2013(S1):800-804. 被引量:1
  • 3张兆镗 钟若青编译.微波加热技术基础[M].电子工业出版社,1998..
  • 4金钦汉 戴树珊 等.微波化学[M].北京:科学出版社,2001..
  • 5Whittaker A G, Mingos D M P. The application of microwave heating to chemical syntheses. J. of Microwave Power and Electromagnetic Engergy. 1994, 29 (4) : 195-219.
  • 6Baghurst D R , Mingos D M P. Design and application of a reflux modification for the synthesis of organometallic compounds using microwave dielectic loss heating effects.J. of Organomel. Chem. 1990, 384:57-60.
  • 7黄瑞祥.微波炉使用维修300问[M].杭州:浙江科学技术出版社,1999.37-38.
  • 8古天乐 黄志洵.截止波导与截止衰减器[M].北京:人民邮电出版社,1977.94--120.
  • 9高福成,陈卫.微波食品[M].北京:中国轻工业出版社,1995.
  • 10陈秉坤,吴鼎.微波炉腔体特性测量,全国微波会议论文集(下册)[C].南昌,1987:1005-1006.

引证文献6

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部