期刊文献+

A Combined-Power Model for the Distribution of Axial Force in Shaft Anchor along Its Length 被引量:1

A Combined-Power Model for the Distribution of Axial Force in Shaft Anchor along Its Length
下载PDF
导出
摘要 The theoretical results of axial force distribution models differ greatly from tests because of the complication of the rock type material. A three-parameter combined-power model is proposed by curves fitting the test data recorded from the pull tests on anchoring bars used in different engineering projects. Based on the comparison of the mechanical characteristics of shaft anchors and prestressed tendons, a two-parameter combined-power function model for prestressed tendons is proposed. The bounded length derived from the model and the suggested values of the parameters are also proposed. Compared with the Gaussian model, the three-parameter combined-power model is more precise and simple in expression. Results also suggest that the bounded length calculated from the average stress method is not safe enough. The theoretical results of axial force distribution models differ greatly from tests because of the complication of the rock type material. A three-parameter combined-power model is proposed by curves fitting the test data recorded from the pull tests on anchoring bars used in different engineering projects. Based on the comparison of the mechanical characteristics of shaft anchors and prestressed tendons, a two-parameter combined-power function model for prestressed tendons is proposed. The bounded length derived from the model and the suggested values of the parameters are also proposed. Compared with the Gaussian model, the three-parameter combined-power model is more precise and simple in expression. Results also suggest that the bounded length calculated from the average stress method is not safe enough.
出处 《Journal of China University of Geosciences》 SCIE CSCD 2006年第1期89-94,共6页 中国地质大学学报(英文版)
基金 This paper is supported by the Foundation for Research Project of ChinaCommunications Second Highway Survey Design and ResearchInstitute .
关键词 axial force prestress tendon bounded length combined-power model Gaussian model axial force prestress tendon bounded length combined-power model Gaussian model
  • 相关文献

同被引文献7

  • 1[1]Freeman T J.The Behavior of Fully-bonded Rock Bolts in the Kielder experimental tunnel[J].Tunnels tunneling.1978:37-40.
  • 2[2]Indraratna B,Kaiser PK.Analytical model for the design of grouted rock bolt[J].Int.J.Numer.Anal.Meth.Geomech.1990,(14):227-251.
  • 3[3]Bjornfot F,Stephansson O.Interaction of grouted rock bolts and hard rock masses at variable loading in a test drift of the Kiirunavaara Mine,Sweden[J].In:Stephansson P,editor.Proceedings of the International Symposium on rock bolting.Rotterdam:Balkema,1984:377-395.
  • 4[5]Yue Cai,Tetsuro Esaki and Yujing Jiang.An analytical model to predict axial load in grouted rock bolt for soft rock tunneling[J].Tunnelling and Underground Space Technology,2004(19):607-618.
  • 5[6]Yue Cai,T.Esaki,Y.J.Jiang.A rock bolt and rock mass interaction model[J].Int.J.Rock.Mech.Min.Sci.,2004(41):1055-1067.
  • 6[9]Malvar L J.Bond reinforcement under controlled confinement[J].ACI Mater J.,1992,89(6):593-601.
  • 7[10]Tao Z,Chen J X.Behavior of rock bolting as tunneling support[J].In:Stephansson O,editor.Proceedings of the International Symposium on Rock Bolting.Rotterdam:Balkema,1984:87-92.