摘要 提出了在酸性条件下左氧氟沙星-Ce(Ⅳ).Na2S2O4化学发光新体系,探讨了该化学发光体系的发光机理.建立了测定左氧氟沙星的流动注射化学发光分析新方法.方法的检出限为7×10^-9g/mL,线性范围为2×10^-8~6×10^-6g/mL,11次平行测定质量浓度为6×10^-7g/mL的左氧氟沙星.其相对标准偏差为2.0%.测定了左氧氟沙星注射液和片剂及血清和尿液中左氧氟沙星的含量,回收率为98.4%~103.7%.结果令人满意. A new chemiluminescence system, levofloxacin-Ce(Ⅳ )-Na2S2O4-H2SO4, was developed for the determination of levofloxacin. The chemiluminescence mechanism of the system was discussed. A new chemiluminescence detection method combined with flow injection was described for the determination of levifloxacin in body fluid and pharmaceutical preparations, The detection limit for levofloxacin is 7 × 10^-9 g/mL, and the relative standard deviation (n = 11) is 2.0% at 6 × 10^-7 g/mL. The linear range is 2 × 10^- 8-6 × 10^- 6 g/mL. The method has been applied to the determination of levofloxacin in body fluid and pharmaceutical preparations ,with satisfactory results.
出处 《河北大学学报(自然科学版)》 CAS 北大核心 2006年第2期161-165,共5页 Journal of Hebei University(Natural Science Edition)
基金 教育部博士点学科基金项目(20050075003)
关键词 化学发光 流动注射 左氧氟沙星 药物 体液 chemiluminescence flow injection levofloxacin pharmaceutical preparations body fluid
  • 相关文献

参考文献12

二级参考文献19

  • 1施毅,夏锡荣,印洁,童茂荣,马宏青,朱维铭,邵海枫,李珍大.国产左旋氧氟沙星治疗细菌性感染的疗效评价[J].医学研究生学报,1999,12(3):5-9. 被引量:5
  • 2赵跃青,孟宪镛,刘艳华.腹水诊断的若干进展[J].国外医学(内科学分册),1993,20(5):213-216. 被引量:7
  • 3曾苏,章立,刘志强.RP-HPLC手性流动相添加剂法分析尿中氧氟沙星对映体[J].药学学报,1994,29(3):223-227. 被引量:24
  • 4袁富山.喹诺酮类药物研究进展[J].国外医药(合成药.生化药.制剂分册),1996,17(2):86-90. 被引量:25
  • 5孔庆芬.第一制药公司的左旋氮氟沙星上市[J].国外药讯,1994,(3):30-30.
  • 61.Nobuki Aoki,Toshimaru Usuda,Yutaka Koda, et al. Clinical pharmacology and efficacy of levofloxacin in elderly patients[J].Jap J Antibiot,1992,45(5)∶530
  • 72.Kenichi Tanaka,Masanori Iwamoto,Shigefumi Maesaki,et al.Laboratory and clinical studies on levofloxacin[J].Jap J Antibiot,1992,45(5)∶548
  • 83.Goodwin SD,Gallis HA,Chow AT,et al.Pharmacokinetics and safety of Levofloxacin in patients with human immunodeficiency virus in fection[J].Antimicrob AG Chemother,1994,38(4)∶799
  • 9[4]Wright DH, Herman VK. Konstantinides FN, Rotschafer JC.Determination of quinolone antibiotics in growth media by reversed-phase high-performance liquid chromatography [J]. J Chromatogr B Biomed Appl, 1998; 709(1) :97-104
  • 10[6]B ttcher S, Baum Hv, Hoppe-Tichy T, Benz C, Sonntag HG.An HPLC assay and a microbiological assay to determine levofloxacin in soft tissue, bone, bile and serum [J]. J Pharm Biomed Anal, 2001;25(2):197-203