期刊文献+

Determination of Trace Amounts of Vanadium by Kinetic-Catalytic Spectrophotometric Methods 被引量:7

Determination of Trace Amounts of Vanadium by Kinetic-Catalytic Spectrophotometric Methods
原文传递
导出
摘要 Kinetic-catalytic spectrophotometric methods were proposed for the determination of trace amounts of vanadium element as vanadium(Ⅳ) and/or V(Ⅴ) ions. The vanadium(Ⅳ) as VO^2+ ion and/or vanadium(Ⅴ) as VO3^- ion showed a catalytic effect on the kinetic reactions between a color reagent such as methylthymol blue (MTB) or SPADNS and bromate in acidic media. The rate of decrease in the absorbance of the reagent MTB at 440 nm or SPADNS at 510 nm was proportional to concentration of V(Ⅳ) and/or V(Ⅴ) ions in the solution. The linear ranges for determination of vanadium were obtained in the range of 1.0-150 and 5.0-100.0 μg/L by the fixed-time and slope methods, respectively, with using MTB as reagent. In the presence of SPADNS as reagent, the calibration curves were made in the amplitude 1.0-200.0 and 5.0-150 μg/L of vanadium ion by the fixed-time and slope methods, respectively. Using fixed-time method, the limits of detection were obtained to be 0.5 and 0.7 μg/L of vanadium in the presence of MTB and SPADNS as reagents, respectively. Detection limits of vanadium by slope method and reagents of SPADNS and MTB were obtained to be 3.5 and 3.8 μg/L of vanadium, respectively. The proposed methods were applied successfully to determination of vanadium in synthetic and real samples. Kinetic-catalytic spectrophotometric methods were proposed for the determination of trace amounts of vanadium element as vanadium(Ⅳ) and/or V(Ⅴ) ions. The vanadium(Ⅳ) as VO^2+ ion and/or vanadium(Ⅴ) as VO3^- ion showed a catalytic effect on the kinetic reactions between a color reagent such as methylthymol blue (MTB) or SPADNS and bromate in acidic media. The rate of decrease in the absorbance of the reagent MTB at 440 nm or SPADNS at 510 nm was proportional to concentration of V(Ⅳ) and/or V(Ⅴ) ions in the solution. The linear ranges for determination of vanadium were obtained in the range of 1.0-150 and 5.0-100.0 μg/L by the fixed-time and slope methods, respectively, with using MTB as reagent. In the presence of SPADNS as reagent, the calibration curves were made in the amplitude 1.0-200.0 and 5.0-150 μg/L of vanadium ion by the fixed-time and slope methods, respectively. Using fixed-time method, the limits of detection were obtained to be 0.5 and 0.7 μg/L of vanadium in the presence of MTB and SPADNS as reagents, respectively. Detection limits of vanadium by slope method and reagents of SPADNS and MTB were obtained to be 3.5 and 3.8 μg/L of vanadium, respectively. The proposed methods were applied successfully to determination of vanadium in synthetic and real samples.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2006年第4期557-562,共6页 中国化学(英文版)
关键词 kinetic-catalytic method SPADNS methylthymol blue VANADIUM kinetic-catalytic method, SPADNS, methylthymol blue, vanadium
  • 相关文献

同被引文献85

引证文献7

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部