摘要 本文对毛细管放电产生类氖氩46.9nm激光进行了实验研究。实验中发现毛细管放电装置中布鲁姆林(Blumlein)传输线所产生的固有预脉冲对软X光激光的产生及稳定输出都有十分不利的影响。为了消除这种影响,提出了用外加隔离开关和隔离电容的方法消除固有预脉冲。经过实验验证,确定了隔离开关和隔离电容的最佳位置。结果该方法能够有效隔离固有预脉冲,使整个放电装置达到稳定运行。在此基础上,得到并改善了毛细管放电类氖氩46.9nm激光输出。 This paper studied the Ne-like argon 46.9nm laser pumped by capillary discharge through experiments. In the experiment, adverse influence of the inherent pre-pulse generated by Blumlein transmission line of the capillary discharge setup on arising and stable output of soft X-ray laser was observed. In order to remove this influence, the method of installing a switch and a capacitor for insulating the inherent pre-discharge pulse is proposed. The experimental results show that the method can insulate the inherent pre-discharge pulse efficiently and the discharge setup reaches stabilization of operation. On the basis of this, the laser spike of Ne-like argon 46.9nm has been observed and improved.
出处 《光电工程》 EI CAS CSCD 北大核心 2006年第3期106-109,共4页 Opto-Electronic Engineering
基金 国家自然科学基金重点资助课题(60038010) 国家高技术863资助课题
关键词 X射线激光 软X光激光 毛细管放电 布鲁姆林(Blumlein)传输线 固有预脉冲 X-ray optics Soft X-ray laser Capillary discharge Blumlein transmission line Inherent pre-pulse
  • 相关文献

参考文献6

  • 1J.J.ROCCA,V.SHLYAPTSEV,F.G.TOMASEL,et al.Demonstration of a discharge pumped table-top soft-X-ray laser[J].Phys.Rev.Lett,1994,73 (16):2192-2195.
  • 2C.D.MACCHIETTO,B.R.BENWARE,J.J.ROCCA.Generation of millijoule-level soft-X -ray laser pulses at a 4-Hz repetition rate in a highly saturated tabletop capillary discharge amplifier[J].Opt.Lett,1999,24 (16):1115-1117.
  • 3A.Ben-Kish,R.A.Nemirovsky,M.Shuker,et al..Parametric investigation of capillary discharge experiment for collisional excitation X -ray lasers[J].SPIE,1999,3776:166-174.
  • 4G.TOMASSETTI,A.RITUCCI,A.REALE,et al.Capillary discharge soft X-ray in Ar pumped by long current pulses[J].Eur.Phys.J.D,2002,19:73-77.
  • 5王骐,刘鹏,赵永蓬,杨大为.毛细管的阻抗特性研究[J].中国激光,2003,30(6):497-500. 被引量:2
  • 6栾伯晗,赵永蓬,吴寅初,程元丽,王骐.毛细管放电抽运软X光激光产生条件的实验研究[J].中国激光,2005,32(9):1189-1192. 被引量:8

二级参考文献13

  • 1李思宁,程元丽,赵永蓬,王骐.毛细管放电条件下类氖序列原子参量计算与分析[J].光学学报,2004,24(11):1581-1584. 被引量:2
  • 2C. D. Maxxhietto, B. R. Benware, J. J. Roeea.Generation of millijoule-level soft-x-ray laser pulses at a 4-Hz repetition rate in a highly saturated tabletop capillary discharge amplifier [J]. Opt. Lett.. 1999. 24(16) :1115-1117.
  • 3A. Ben-Kish. R. A. Nemirovsky. M. Shuker et al .Parametric investigation of capillary discharge experiment for collision excitation X-ray lasers [C]. SPIE, 1999,3776 : 166 - 174.
  • 4G. Niimi, Y. Hayashi. M. Nakajima et al..Observation of multi-pulse soft X-ray lasing in a fast capillary discharge [J]. J. Phys. D: Appl. Phys .2001. 34:2123-2126.
  • 5J. J. Rocca, V. Shlyaptsev, F. G. Tomasel et al..Demonstration of a discharge pumped table-top soft-X-ray laser[J]. Phys. Rev. Lett., 1994, 73(16):2192-2195.
  • 6A. Ben-Kish, R. A. Nemirovsky, M. Shukeretal.. Parametric investigation of capillary discharge experiment for collisional excitation X-ray lasers [C]. SPIE, 1999, 3776:166-174.
  • 7Gohta Niimi, Yasushi Hayashi, Mitsuo Nakajima et al..Observation of multi-pulse soft x-ray lasing in a fast capillary discharge[J]. J. Phys. D.. Appl. Phys., 2001, 34:2123-2126.
  • 8Hiroyuki Daido. Review of soft x-ray laser researches and developments [R]. Rep. Prog. Phys. , 2002, 65:1513-1576.
  • 9J. J. Rocca, D. P. Clark, J. L. A. Chilla et al.. Energy extraction and achievement of the saturation limit in a dischargepumped table-top soft X-ray amplifier[J]. Phys. Rev. Lett. ,1996, 77(8) : 1476- 1479.
  • 10Gohta Niimi. Yasushi Hayashi, Nobuhiro Sakamoto et al..Development and characterization of a low current capillarydischarge for X-ray laser studies[J]. IEEE Transactions on Plasma Science, 2002, 30(2) : 616 -621.

共引文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部