摘要
结合三门峡华阳发电有限责任公司输煤程控系统应用情况,对该系统故障进行了统计分析。分析表明,其主要干扰为外部干扰。对此,从硬件和软件两方面提出了外部设备抗干扰的几种措施。
Combined with application situation of programmable control system for coal handling in Huayang Power-Generation Co Ltd, the various interference factors existing in practical application of programmable control system for coal handling have been analysed. For these, several interference rejection measures for external equipments have been put forward from two aspects, namely hardwares and softwares.
出处
《热力发电》
CAS
北大核心
2006年第3期57-58,66,共3页
Thermal Power Generation
关键词
输煤程控
电磁干扰
继电器隔离
接地
屏蔽
数字滤波
软件容错
programmable control of coal handling
electro-magnetic interference
separation of relays
grounding shield
digital filtering
error-tolerence of software