期刊文献+

流动注射荧光法测定甲硝唑 被引量:3

Determination of Metronidazole by flow injection fluorimetric
下载PDF
导出
摘要 采用铁-冰醋酸还原体系,将甲硝唑还原后,在激发波长354 nm,发射波长426 nm处测定其荧光强度,据此建立了甲硝唑的荧光分析法。实验表明,甲硝唑浓度在1.0×10-6mol/L^5.0×10-4mol/L范围内与其荧光强度呈良好的线性关系,相对标准偏差(RSD)为1.05%,检出限为1.75×10-7mol/L。本法已用于甲硝唑片剂和甲硝唑葡萄糖注射液中甲硝唑含量的测定,结果令人满意。 A fast and simple method for the determination of Metronidazole by fluorescence is described based on its emission intensity at 426nm in water medium when excited at 354nm. The linear calibration graph is 1.0 × 10^-6 5.0 × 10^-4 mol/L. The relative standard deviation is 1.05%. The detection limit is 1.75 × 10^-7mol/L. The proposed method has been successfully applied to the determination of Metronidazole in tablets and injection with satisfactory results.
出处 《南阳师范学院学报》 CAS 2006年第3期38-41,共4页 Journal of Nanyang Normal University
基金 河南省科技厅自然科学基金资助项目(0311021700)
关键词 甲硝唑 荧光法 还原 测定 Metronidazole fluorimetric reduction determination
  • 相关文献

参考文献9

二级参考文献18

共引文献36

同被引文献97

引证文献3

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部