动态血糖监测系统——CGMS的临床回顾及展望 被引量:2

下载PDF
导出
出处 《解放军医学杂志》 CAS CSCD 北大核心 2006年第4期366-367,共2页 Medical Journal of Chinese People's Liberation Army
  • 相关文献

参考文献14

  • 1Albisser AM,Leibel BS,Johnson W et al.An improved technique for the rapid continuous measurement of whole blood glucose,suitable for clinical application in an artificial endocrine pancreas.Med Prog Technol,1977,5:141
  • 2Layne EC,Schultz RD,Thomas LJ et al.Continuous extracorporeal monitoring of animal blood using the glucose electrode.Diabetes,1976,25:81
  • 3Salardi S,Zucchini S,Santoni R et al.The glucose area under the profiles obtained with continuous glucose monitoringsystem relationships with HbA(lc) in pediatric type 1 diabetic patients.Diabetes Care,2002,25:1840
  • 4喻明 周健.动态监测糖耐量正常者血糖水平的漂移变化[J].Natl Med J China,2004,11(2):84-84.
  • 5Boland E,Monsod T,Delucia M et al.Limitations of conventional methods of self-monitoring of blood glucose:lessons learned from 3 days of continuous glucose sensing in pediatric patients with type 1 diabetes.Diabetes Care,2001,24:1858
  • 6Weintrob N,Schechter A,Benzaquen H et al.Glycemic patterns detected by continuous subcutaneous glucose sensing in children and adolescents with type 1 diabetes mellitus treated by multiple daily injections vs continuous subcutaneous insulin infusion.Arch Pediatr Adolesc Med,2002,158:677
  • 7喻明,周健,项坤三,李鸣,李青,周逸常.动态监测新诊断2型糖尿病患者的血糖水平[J].中华糖尿病杂志(1006-6187),2005,13(2):102-104. 被引量:87
  • 8Hay LC,Wilmshurst EG,Fulcher G.Unrecognized hypo-and hyperglycemia in well-controlled patients with type 2 diabetes mellitus:the results of continuous glucose monitoring.Diabetes Technol Ther,2003,5:19
  • 9Kerssen A,Evers IM,de Valk HW et al.Poor glucose control in women with type 1 diabetes mellitus and 'safe'hemoglobin A1c values in the first trimester of pregnancy.J Matern Fetal Neonatal Med,2003,13:309
  • 10Ben-Haroush A,Yogev Y,Chen R et al.The postprandial glucose profile in the diabetic pregnancy.Am J Obstet Gynecol,2004,191:576

二级参考文献7

  • 1Gross TM, Bode BW, Einhorn D, et al. Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther,2000,2:49-56.
  • 2Mastrototaro J. The MiniMed continuous glucose monitoring system(CGMS). J Pediatr Endocriol Metab, 1999,12:751-758.
  • 3Bode BW, Gross TM, Thornton KR, et al. Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin. Diabetes Res Clin Pract, 1999,46:183-190.
  • 4Boyne MS, Silver DM, Kaplan J, et al. Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor. Diabetes, 2003, 52:2790-2794.
  • 5Steil GM, Rebrin K, Mastrototaro J, et al. Determination of plasma glucose during rapid glucose excursions with a subcutaneous glucose sensor. Diabetes Technol Ther,2003,5:27-31.
  • 6Kaufman FR, Carpenter S, Gibson LC, et al. A pilot study of the continuous glucose monitoring system. Diabetes Care, 2001,24:2030-2034.
  • 7Rohlfing CL, England JD, Wiedmeyer HM, et al. Defining the relationship between plasma glucose and HbA1c. Diabetes Care, 2002,25:275-278.