摘要
目的探讨计算机X摄影在新生儿床旁胸片检查中的价值。方法抽取我院计算机X摄影和传统X线摄影新生儿床旁胸片各200份,由3位主管技师对照片进行分析,统计甲、乙、丙及废片率。结果计算机X摄影照片甲级片率为52.5%,乙级片率35.0%,丙级片率12.0%,废片率0.5%;传统X线摄影照片甲级片率为41.0%,乙级片率42.5%,丙级片率15.0%,废片率1.5%。结论计算机X摄影新生儿床旁胸片质量好于传统X摄影,值得广泛应用。
Objective: To investigate the value of computed radiography on bedside chest films of newborn infant. Methods: Two hundred cases of computed radiographic films and 200 traditional X - ray radiographic films of newborn infants were selected from our hospital to be analysed by 3 radiologists respectively, Results. With computed radiography the quality of the films was classified into grade A 52.5%, grade B 35.0%, grade C12.0%, and waste 0.5% ; with traditional X - ray radiography, the quality of the films was classified into grade A41.0%, grade B42.5%, grade C15.0%, and waste 1.5%. Conclusion; The quality of computed radiography is better than traditional X - ray radiography on bedside chest films of newhom infant, and it should be widely applied.
出处
《泰山医学院学报》
CAS
2005年第4期306-307,共2页
Journal of Taishan Medical College
关键词
计算机X摄影
床旁胸片
新生儿
computed radiography
bedside chest film
newborn infant