期刊文献+

CMGA:一个利用钚的94—104keV γ和X射线非破坏分析其同位素丰度的软件 被引量:2

CMGA: a code to assay abundances of plutonium isotopes non-destructively with γ and X-rays in 94—104 keV energy range
下载PDF
导出
摘要 钚样品γ能谱94—104keV能区中有22条X及γ射线可用来提供其同位素丰度信息。本文介绍我们开发的用来解析该能区的CMGA1.0(ChinaMultipleGroupAnalysis,Version1.0)软件。利用该软件分析当前我们所能取得的唯一的具有质谱分析结果的样品。其240Pu/(239Pu+240Pu)多次测量的平均值与质谱法给出的对应数值之比为1.004,相对标准偏差为1.4%。 A multi-channel spectrum of plutonium samples measured by HPGe detector includes 22 γ or X-ray lines in the 94--104 keV energy range, which can be used to provide information on the abundances of plutonium isotopes. A code named as CMGA (China Multi-Group Analyzer, Version 1.0), developed to unfold this region, is introduced in this paper. One and only one plutonium sample we can obtain was measured 19 times and the results of ^240pu/(^239pu+^240pu) given by CMGA are presented. The ratio of the mean ^240pu/(^239pu+^240pu) value from repeated measurements given by CMGA to that given by mass spectrum analysis is 1.004 with a relative standard deviation around ±1.4%.
出处 《核技术》 CAS CSCD 北大核心 2006年第4期257-260,共4页 Nuclear Techniques
基金 中国博士后科学基金资助项目(2005038035)
关键词 钚同位素丰度 多道γ能谱 非破坏分析 Plutonium isotopes abundances, Multi-channel γ ray spectrum, Non-destructive assay
  • 相关文献

参考文献13

  • 1Nondestructive uranium-235 enrichment assay by gamma ray spectrometry.United States Atomic Energy Commission Regulatory Guide 5.21,April,1974
  • 2Klosterbuer S F,Halbig J K.NaI 235U enrichment measurement Users Manual,revised February 16,1990,Los Alamos National Laboratories,New Mexico,USA
  • 3Gunnink R,Ruhter W,Miller P,et al.MGAU:A new analysis code for measuring U-235 enrichments in arbitrary samples.Presented at the IAEA Symposium on International Safeguards,Vienna,Austria,Mar.8-14,1994
  • 4Gunnink R.MGA:A gamma-ray spectrum analysis code for determining plutonium isotopic abundances.Lawrence Livermore National Laboratory Report UCRL-LR-03220,April 1990
  • 5Verplancke J,Van Dyck P,Tench O,et al.The U-Pu inspector system:a dedicated instrument for assessing the isotopic composition of uranium and plutonium,Presented at the 17th ESARDA Symposium,May 9-11,1995,Aachen,Germany
  • 6Verplancke J,Davidson D,Koskelo M,et al.Applying MGA for waste characterization.Presented at the WM95 Conference,Feb 26-Mar 2,1995,Tucson,Arizona,USA
  • 7Thomas A K,Thomas E S,Ronald M K,et al.Recent developments of LANL PC/FRAM Code,LANL Number UR-99-2010
  • 8Koskelo M,Savlov A,Vzorov D,et al.A new version of MGA for highly attenuated Pu samples,Presented at the HPS Mid-Year Meeting in Alberquerque,January 1999
  • 9龚建,黄凌.两种钚同位素丰度无损分析技术方法的实验比较研究[J].核技术,2003,26(10):767-770. 被引量:5
  • 10唐培家,李鲲鹏.γ能谱法测定铀、钚同位素丰度[J].同位素,2001,14(3):166-173. 被引量:12

二级参考文献13

  • 1李泽,崔安智,刘大鸣,刘永辉,王秀芝,敬克兴,唐培家,杨毅,张淑兰,李新华,孙宏清,刘从贵,李大明,张生栋,安新宇,郭景儒.^(95)Zr、^(140)Ba和^(147)Nd产额的精确测定[J].核化学与放射化学,1995,17(2):65-72. 被引量:4
  • 2Hsue S T, Stewart J E, Sampson T E, et al. Guide to nondestructive assay standards: preparation criteria, availability, and practical considerations. LA-13340-MS, 1997,USA. 66-68.
  • 3Sampson T E. Plutonium isotopic composition by gamma-my spectroscopy: A review. LA-10750-MS, 1986,USA. 25--27.
  • 4Kelley T A. PC/FRAM: Algorithms for the gamma-ray spectrometry measurement of plutonium isotopic composition, LA-UR-95-3326, 1995, USA. 3--5.
  • 5Gunnink R. MGA: A gamma-ray spectrum analysis code for determining plutonium isotopic abundances.UCRL-LR-103220, 1990, USA. 2--3.
  • 6Gunnink R, Evans J E, Prindle A L. Gamma rays from the plutonium isotopes and their daughters. UCRL-52139,1997, USA. 5--9.
  • 7Wang Liyu,Appl Radiat Isot,1989年,40卷,575页
  • 8团体著者,原子核物理实验方法.上(第2版),1985年,375页
  • 9王思广,中国原子能科学研究院第十一届五四青年学术报告会文集.物理部分,1997年,42页
  • 10Shirley VS. Table of Isotopes (Eighth Edition)[Z]. New York: Lawrence BerkeleyNational Laboratory, 1996.

共引文献23

同被引文献5

  • 1WANG T F.Past,present,and future of MGA++,LLNL-PRES-407782[R].USA:Lawrence Livermore National Laboratory,2008.
  • 2THOMAS E S,DUCT V.FRAM development history,code operation,capability and limitations,LA-UR-08-05887[R].USA:Los Alamos National Laboratory,2008.
  • 3THOMAS E S.Plutonium isotopic composition by gamma-ray spectroscopy,LA-10750-MS[R].USA:Los Alamos National Laboratory,1986.
  • 4GUNNINK R,EVANS J E,PRINDLE A L.A reevaluation of the gamma-ray energies and abso-lute branching intensities of 237U,238,239,240,241Pu,and 241Am,UCRL-52139[R].USA:Lawrence Livermore Laboratory,1976.
  • 5THOMAS E S,THOMAS A K,DUC T V.Application guide to gamma-ray isotopic analysis using the FRAM software,report LA-14018[R].USA:Los Alamos National Laboratory,2003.

引证文献2