期刊文献+

介质阻挡放电和介质阻挡电晕放电灭菌效果的试验研究 被引量:2

Experimental Research on Inactivation Bacteria Effect of DBD and DBCD
下载PDF
导出
摘要 应用介质阻挡放电(DBD)和介质阻挡电晕放电 (DBCD)产生的低温等离子体,对金黄色葡萄球菌和大肠杆菌进行杀灭试验的结果发现,在90s内DBD和DBCD都对金黄色葡萄球菌和大肠杆菌的杀灭对数值KL达到了5。 DBCD使两种菌株减少的速度大于DBD。DBD和DBCD都使大肠杆菌减少的速度大于金黄色葡萄球菌。 E.coli and S.aureus are treated with the low- temperature plasma induced by the dielectric barrier discharge (DBD) and dielectric barrier corona discharge (DBCD) respectively, it is found that the killing logarithms of the low-temperature plasma induced by DBD and DBCD on the two strains reached 5 within 90 s of exposure. DBCD decreases the number of the two strains faster than DBD. Both DBD and DBCD decreases the number of E.coli faster than those of S.aureus.
出处 《高压电器》 EI CAS CSCD 北大核心 2006年第2期120-121,124,共3页 High Voltage Apparatus
关键词 介质阻挡放电 介质阻挡电晕放电 金黄色葡萄球菌 大肠杆菌 dielectric barrier discharge(DBD) dielectric barrier corona discharge (DBCD)S.aureus E.coli
  • 相关文献

参考文献4

  • 1孙岩洲,石兴民,王辉,印华,邱毓昌.介质阻挡放电杀灭枯草杆菌芽孢的电镜观察[J].高压电器,2005,41(1):10-11. 被引量:11
  • 2Pekarek S,Balek R.Ozone and Nitrogen Oxides Generation in Gas Flow Enhanced Hollow Needle to Plate Discharge in Air[J].Ozone:Science and Engineering,2002,24(3):221-226.
  • 3Gegolewski S,Mainil Varlet P,Dillon JG.Sterility Mechanical Properties and Molecular Stability of Polylactide Internal Fixatin Devices Treated with Low Temperature Plasma[J].J Biomed Mater Res,1996,32(2):227.
  • 4Alfa M J,Degagne P,Olson N,et al.Comparison of Ion Plasma,Vaporized Hydrogen Peroxide,and 100% Ethylene Oxide Sterilizers to the 12/88 Ethylene Oxide Gas Sterilizer[J].Infect Control Hosp Epidemiol,1996,17(2):92.

二级参考文献6

共引文献10

同被引文献27

引证文献2

二级引证文献11