期刊文献+

混凝沉淀法处理低含磷废水实验研究 被引量:13

Experiments on Removal of Low P Content Wastewater by Coagulation Method
下载PDF
导出
摘要 城市污水处理厂二级出水中含磷浓度较低,要达到回用标准仍需进一步去除。利用FeCl3、FeSO4、Al2(SO4)3 和聚合氯化铝(PAC)四种混凝剂在室温条件下对含磷浓度为1.2mg/L的城市污水处理厂出水进行混凝处理,寻找最佳处理效果的投药量和pH值。实验表明,欲使处理后出水总磷浓度达到地表水环境质量标准Ⅲ类水质标准,FeCl3 的最佳投药量为30mg/L,最佳pH为7.24-9.00;Al3(SO4)3的最佳投药量为50mg/L,最佳pH为6.92-8.04;PAC的最佳投药量为30mg/L,最佳pH为7.24-7.94,而FeSO4对磷的去除效果较差,当投药量达70mg/L时,去除率仅为23.33%。 Although phosphate concentration in the secondary effluent of sewage treatment plant is low, the phos-phate concentration should be decreased further if it is wanted to keep compliance with quality of the reuse water standard. Low P content waste water with P of 1.2mg/L was treated by coagulation using 4 kinds of coagulant: FeCO3.FeSO4.Al2(SO4)3 and polyaluminum chloride(PAC). In order to find the optimum coagulant dosage and pH to make the treated wa-ter in accordonce with the quality of Ⅲ category surface water of the standard GB3838-2002. The experimental results in-dicated that the optimum pH and dosage are 7.24-9.00 and 30mg/L with Fecl3 used as coagulant, 7.24-7.90 and 30mg/L with PAC,6.92-8.04 and 50mg/L with Al2(S04)3. When FeSO4 is used and it's dosage increased to 70mg/L, the removalrate of P is only 23,33%.
出处 《净水技术》 CAS 2006年第2期46-48,共3页 Water Purification Technology
基金 桂林市水环境质量改善与综合示范项目(国家高技术研究发展计划(863计划)(2003AA601060-02)
关键词 低含磷废水 混凝沉淀 除磷 混凝剂 wastewater of low P content coagulation and sedimentation phosphorus removal coagulant