期刊文献+

300kVA高温超导变压器电流引线漏热损耗的测量 被引量:1

An experiment on measuring the heat loss of the current lead of 300kVA HTS transformer
下载PDF
导出
摘要 电流引线是高温超导变压器的主要外部漏热来源,它的漏热量直接影响了超导变压器的经济性能,因此,引线的设计与漏热测量一直备受关注。文中构建了一个实验方案,运用量热法测量低压引线的漏热,并将试验结果与仿真预期值进行了对比和分析,从而验证了仿真设计的正确性。 The current lead of HTS transformer is a part that leads to leak out heat, its design and fabrication influence greatly the loss of nitrogen during operation. It is importance to calculate and identify the heat leak of the current lead. Based on heat transfer theory, this paper designed an experiment to measure the heat loss of the current lead of 300kVA transformer and analyzed the data of the experiment. The experimental results show a good according with the simulation.
出处 《低温与超导》 CAS CSCD 北大核心 2006年第2期114-117,共4页 Cryogenics and Superconductivity
基金 国家863计划项目(2002AA306371) 973计划项目(2004CB217906)
关键词 高温超导变压器 引线 漏热 损耗 HTS transformer, Current lead, Leakage heat, Loss