期刊文献+

An advanced irradiation facilities and its usage

An advanced irradiation facilities and its usage
下载PDF
导出
摘要 A carrier type gamma irradiator is an advanced device currently installed in Qingdao Irra- diation Center (QIC) and has been put into operation for nine years in Qingdao, China. It utilizes Co-60 as the radiation source; the initial Co-60 loading is 1.48×1016 Bq (0.4 million Curies). Rubber, natural and synthetic polymers, heat-shrinkable films and tubes, disposable medical supplies, some foods and drugs have been irradiated for test in the past. Especially a great success achieved on the radiation of compound food for young shrimp. The practice demonstrates that the bacteria in the compound food can be de- stroyed by the irradiation at optimum dosage between 5 000–6 000 Gy. A carrier type gamma irradiator is an advanced device currently installed in Qingdao Irradiation Center (QIC) and has been put into operation for nine years in Qingdao, China. It utilizes Co-60 as the radiation source; the initial Co-60 loading is 1.48×10^16Bq (0.4 million Curies). Rubber, natural and synthetic polymers, heat-shrinkable films and tubes, disposable medical supplies, some foods and drugs have been irradiated for test in the past. Especially a great success achieved on the radiation of compound food for young shrimp. The practice demonstrates that the bacteria in the compound food can be destroyed by the irradiation at optimum dosage between 5 000--6 000 Gy.
出处 《Chinese Journal of Oceanology and Limnology》 SCIE CAS CSCD 2006年第2期212-214,共3页 中国海洋湖沼学报(英文版)
基金 Supported by National Natural Science Foundation of China (No. 40276026), and also by Open Foundation of State Key Laboratory of Estuarine and Coastal Research, East China Normal University (No. 200406).
关键词 irradiator Co-60 compound food young shrimp BACTERIA 伽玛射线 辐射度 化合物 海洋资源 地质勘探
  • 相关文献

参考文献9

  • 1Brinston,R.M.and B.K.Wilson,1993.Converting to gamma radiation sterilization:An overview for medical device manufacturers.Medical Device Technology 4(4):18-22.
  • 2Ehlermann,D.A.,1995.Dosimetry and identification as a tool for official control of food irradiation.Radiat.Phys.Chem.46(4-6):693-698.
  • 3Gupta,B.L.and R.M.Bhat,2001.Irradiation temperature effect on glutamine dosimeter.Radiat.Phys.Chem.61(1):41-48.
  • 4Harry,F.,1995.Placement of dosimeters and radiation sensitive indicators.Radiat.Phys.Chem.46(4-6):1 353-1 357.
  • 5Henon,Y.M.,1995.Food irradiation in perspective.Radiat.Phys.Chem.46(4-6):647-651.
  • 6International Atomic Energy Agency,1992.Radiation safety of gamma and electron irradiation facilities,Safety Series No 107,IAEA,Vienna.
  • 7James,L.W.,1993.Microbiological aspects relating to the choice of radiation sterilization dose.Radiat.Phys.Chem.42(4-6):577-580.
  • 8Uigao,A.B.and N.F.Mendes,2002.Temperature rising elution fractionation,infra red and rheology study on gamma irradiated HMSPP.Radiat.Phys.Chem.63 (3-6):509-516.
  • 9Wang,G.,Z.Liu and Z.Wei.1993.Co-60 radiation crosslinked polyethylene heat-shrinkable material.Radiat.Phys.Chem.42(1-3):107-108.