期刊文献+

预应力芳纶纤维布加固混凝土梁的受剪承载力试验研究 被引量:2

EXPERIMENTAL STUDY ON SHEAR CAPACITY OF RC BEAMS STRENGTHENED WITH PRESTRESSED AFRP SHEETS
下载PDF
导出
摘要 通过7根芳纶纤维布加固钢筋混凝土梁的抗剪性能试验,研究了芳纶纤维布的预应力水平及加固形式对混凝土梁抗剪承载力的影响。试验结果表明,带永久锚具的预应力芳纶纤维布加固混凝土梁与非预应力芳纶纤维布加固混凝土梁相比,其开裂荷载显著提高,屈服荷载与极限荷载明显提高;预应力芳纶纤维布加固混凝土梁的抗剪承载力随着纤维布预应力水平的提高而增大。 Based upon the experimental study on shear bearing capacity of seven strengthening RC beams using aramid fiber reinforced plastic (AFRP) sheets, the effects of different prestress levels and different shear strengthening measures on shear bearing capacity of RC strengthening beams were researched. The experimental results show that as compared with the beams strengthened with non-prestressed AFRP sheets, the initial cracking load of the beam strengthened with prestressed AFRP sheets is increased significantly, at the same time, the yield load and ultimate load are increased significantly; when the prestressed level of AFRP sheet is gradually increased, the shear bearing capacity of the strengthened beams is also gradually increased.
出处 《工业建筑》 CSCD 北大核心 2006年第4期19-22,共4页 Industrial Construction
基金 北京市自然科学基金重点项目(编号:8051001) 北京市教委项目(编号:KM10005007)
关键词 预应力 芳纶纤维布 永久锚具 加固 混凝土梁 prestress AFRP sheet permanent anchor strengthening RC beam
  • 相关文献

参考文献6

  • 1Triantafillou Thanasis C, Deskovic Nikola. Innovative Pestressing with FRP Sheets: Mechanics of Short-Term Behaviors. Journal of Engineering Mechanics, 1991, 117(7): 1 652-1 672
  • 2Triantafillou T C. Deskovie N, Deuring M. Strengthening Concrete Structures with Prastressed Fiber Reinforced Plastic Sheets. ACI Struct.J., 1992, 89(3): 235-244
  • 3Meier U. Strengthening of Structures Using Carbon Fiber/Epoxy Composites. Constr. And Build. Mat., 1995, 9(6): 341-351
  • 4飞渭,江世永,彭飞飞,陈正平,李庆枫,陈龙.预应力碳纤维布加固混凝土受弯构件试验研究[J].四川建筑科学研究,2003,29(2):56-60. 被引量:104
  • 5周仕刚,高永飞.CFRP加固初始受载钢筋砼梁弯曲性能的试验研究[J].玻璃钢/复合材料,2003(1):3-6. 被引量:141
  • 6Raafat El-Hacha M A, R Gordon Wight, Mark F Green. Prestressed Carbon Fiber Reinforced Polymer Sheets for Strengthening Concrete Beams at Room and Low Temperatures. Journal of Composites for Construction. 2004, 8(1): 3-13

二级参考文献8

  • 1Hollaway L C, Head P R. Advanced Polymer Composites and Polymers in the Civil Infrastructure. ELSEVIER, 109-158,2001.
  • 2Hamid Saadatmanesh, Mohammad R. Ehsani. RC Beams Strengthened with GFRP Plates: Part I : Experimental Study Journal of Structural Engineering. November, 1991,3417-3433.
  • 3Wight R G,EI-Hacha R. CFRP Sheet Strengthening DamagedC~ntinuous Reinforced C~ncrete Beams, International C~rtferenceon FRP C~mposites in Civil Engineering,433-441,2001.
  • 4叶列平等.碳纤维布加固钢筋混凝土板二次受力性能的试验研究.中国纤维增强塑料混凝土结构学术交流会,2000:83-91
  • 5G.Spadea,F.Bencardino.Structural behavior of composite RC beams with externally bonded CFRP.J.of Composites for Construction,1998:132~137
  • 6Omar Chaallal,Thomas E. Beitelman.Flexural strengthening with carbon fiber reinforced polymer composites of preloaded full-scale girders.ACI Structural,2001:735~742
  • 7岳清瑞,陈小兵,牟宏远.碳纤维材料(CFRP)加固修补混凝土结构新技术[J].工业建筑,1998,28(11):1-5. 被引量:95
  • 8胡孔国,岳清瑞,叶列平,孙燕.碳纤维布加固混凝土桥面板受弯性能试验研究[J].建筑结构,2000,30(7):44-48. 被引量:41

共引文献186

同被引文献27

引证文献2

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部