不完全冻结式冰盘管充气融冰的实验研究 被引量:2

Experiment of the partial charged ice-on-coil with aerated discharging
下载PDF
导出
摘要 分析了不完全冻结式冰盘管在融冰过程中的传热特性,提出了在融冰时充入空气以提高蓄冰槽传热性能的建议。实验结果表明,充气融冰可以大大提高蓄冰槽的传热性能,充气量对蓄冰槽传热性能的影响不大。 Analyses the heat transfer performance of the partial charge mode during discharging periods. Presents a suggestion to improve the heat transfer performance of the ice storage tank by aeration. The experimental results show that the performance of the tank can be improved obviously by aeration and the effect of air volume on the performance of the tank is insignificant,
机构地区 浙江大学
出处 《暖通空调》 北大核心 2006年第4期106-108,共3页 Heating Ventilating & Air Conditioning
关键词 冰蓄冷 融冰过程 充气 实验研究 ice storage, discharging period, aeration, experiment
  • 引文网络
  • 相关文献

参考文献5

  • 1Neto J H M,Krarti M.Experimental validation of a numerical model for an internal melt ice-on-coil thermal storage tank[G]∥ASHRAE Trans,1997,103(1):125-138
  • 2Nelson D J,Vick B,Yu X.Validation of the algorithm for ice-on-pipe brine thermal storage systems[G]∥ASHRAE Trans,1996,102(1):55-62
  • 3周伟坤,李海军,陈国邦.内融式冰盘管完全冻结与不完全冻结的比较[J].暖通空调,2005,35(8):96-98. 被引量:2
  • 4孔珑.工程流体力学[M].2版.北京:水利电力出版社,1992
  • 5郭荣良,郭清南,祝世兴.流体力学及应用[M].北京:机械工业出版社,1995

二级参考文献5

  • 1Chaichana C, William W S, Lu A. An ice thermal storage computer model. Applide Thermal Engineering, 2001, 21:1769 - 1778
  • 2Jekel T B, Mitchell J W, Klein S A. Modeling of icestorage tanks. In: ASHRAE Trans. 1993, 99(1). 1016- 1023
  • 3Neto J H M, Krarti M. Experimental validation of a numerical model for an internal melt ice-on-coil thermal storage tank. In: ASHRAE Trans. 1997,103(1). 125- 138
  • 4Nelson D J, Vick B, Yu X. Validation of the algorithm for ice-on-pipe brine thermal storage systems. In:ASHRAE Trans. 1996,102(1). 55 - 62
  • 5Neto J H M, Krarti M. Deterministic model for an internal melt ice-on-coil thermal storage tank. In:ASHRAE Trans. 1997,103(1). 113 - 124

共引文献1

同被引文献1

  • 1马最良,吕悦.地源热泵系统设计与应用[M].北京:机械工业出版社,2006.

引证文献2

二级引证文献3

;
使用帮助 返回顶部