摘要
目的:提高他克莫司血药浓度监测结果的准确性。方法:采用酶联免疫吸附分析法测定他克莫司血药浓度高、低质控各60点,绘制质控图,对监测过程进行预防性和回顾性质量控制。结果:可依据质控图对监测结果加以判断。结论:质量控制能有效提高他克莫司血药浓度监测结果的准确度,并可预防及纠正系统误差。
OBJECTIVE: To increase the accuracy of blood concentration monitoring results of tacrolimus. METHODS: Blood concentrations of tacrolimus (60 points for high and low quality control, respectively) were determined by enzymelinked immunosorbent assay and the quality control graphs were drawn. The whole monitoring course underwent both prospective and retrospective quality control. RESULTS: The quality control monitoring results could be evaluated from the quality control graphs. CONCLUSION: Quality control can effectively increase the accuracy of blood concentration monitoring results of tacrolimus, which can also prevent and rectify systemic error.
出处
《中国药房》
CAS
CSCD
北大核心
2006年第8期600-601,共2页
China Pharmacy