UBF处理垃圾渗滤液的中试研究 被引量:11

Pilot experiment study of landfill leachate using UBF process
下载PDF
导出
摘要 采用复合厌氧反应器UBF(UASB与AF复合反应器)对垃圾渗滤液进行了处理.结果表明:在温度15.3- 35.2℃,水力停留时间为6 d条件下,当进水CODCr质量浓度为5 431—8 723 mg/L、BOD5质量浓度为 1 633.5~3 124.2 mg/L时,CODCr、BOD5去除率分别为70.6%-73.9%和74.5%~78.1%.在冬季8~15℃的低温条件下,水力停留时间仍为6 d,通过外加污泥,可使CODCr、BOD5的去除率分别保持在70%、75%左右. The landfill leachate is treated by combination anaerobic reactor UBF. The results show that under the conditions of which the temperature is 15.3 - 35.2℃ and HRT is 6 d, the removal efficiencies of CODe, and BODs are 70.6% -73.9% and 74.5% - 78.1%, respectively when CODe,. concentration of inlet ranges is 5 431 - 8 723 mg/L and BOD8 is 1 633.5 - 3 124.2 mg/L. The removal efficiencies of CODcr and BOD5 are still 70% and 75%, respectively, by putting sludge into the reactor when the temperature is 8 - 15℃ and HRT is 6 d in winter.
出处 《天津工业大学学报》 CAS 2006年第2期44-47,共4页 Journal of Tiangong University
关键词 复合厌氧反应器 UBF 垃圾渗滤液 厌氧生物处理 anaerobic combination processor UBF( UASB + AF) landfill leachate anaerobic bio-treatment