摘要
锅炉连排流量是电厂在线性能监测中一项必须测量的项目,对计算锅炉侧吸热量影响较大。通过测量定排流量,及连排、定排的其它热力参数,可以直接计算出锅炉连排的流量,并提出了在线监测计算连排流量的具体方法。
The boiler continuous blowdown flow is one of the measurements which must be made for online performance monitoring of power plant, and has a direct impact on the calculation of boiler heat absorption. This article introduced one method to calculate the boiler continuous flow by measuring the intermittent blowdown flow and other thermal parameters of continuous and intermittent blowdown, and give the concrete method for calculation of continuous blowdown flow for online performance monitoring.
出处
《华北电力技术》
CAS
2006年第4期10-11,19,共3页
North China Electric Power
关键词
锅炉
连排
流量
测量
boiler
continuous blowdown
flow
measurement