目的:研究大鼠心肌缺血再灌注损伤后三磷酸腺苷(ATP)的含量的变化.方法:应用反相离子对高效液相色谱法(HPLC)分离测定,流动相为 0.1 mmol/L KH2PO4+8 mmol/L 氢氧化四丁铵,检测波长259nm.结果:ATP标准液与峰面积呈良好的线性关系(r=0.998).重复测定不同浓度ATP标准液精密度(变异系数)1.91%~5.78%.回收率为97.25%~100.05%.结论:反相离子对高效液相色谱法可以准确测定大鼠心肌组织ATP的含量.
Objectlve:To study the change alteration of ATP in the rat heart with ischemia reperfusion injury by Ion-pair reversed-phase HPLC. Methods: Ion-pair reversed-phase HPLC methods was developed for determination of ATP. The solvent consist of 0. 1 mmol · L^-1 KH2PO4 ; 8 mmol · L^-1 tetrabutylammonium hydrogen. The separation was monitored at 259nm. Results:The calibration curve showed good linearity ( r = 0. 998 ) . The coefficients of variation ( C. V) were estimated from repeated determinations of standard ATP. The intraassay C. V varied from 1.91% to 5.78%. The recovery was between 97.25% and 100.05%. Conclusions:This methods is precise,it can be used for determination of ATP in the rat heart.
出处
《军医进修学院学报》
CAS
北大核心
2006年第2期134-135,共2页
Academic Journal of Pla Postgraduate Medical School
基金
保定市科技局资助项目(99F008)