期刊文献+

16层CT在肺动脉栓塞诊断及治疗中的应用价值

The evaluation of clinical application of 16 slice spiral computer tomography for diagnosis and treatment of pulmonary embolism
下载PDF
导出
摘要 目的探讨16层螺旋CT在肺动脉栓塞诊断价值及临床溶栓治疗后效果评估。方法对30例临床疑诊肺动脉栓塞患者均进行16层螺旋CT肺动脉增强扫描。2例患者一周后复查。结果25例患者肺动脉成像未见异常,5例影像学明确诊断肺动脉栓塞,2例经溶栓治疗后一周复查,病灶基本消失,2例临床溶栓治疗后症状消失,1例死亡。结论16层螺旋CT能够及时准确诊断肺动脉栓塞,对于指导治疗及评价治疗效果是一种可靠的方法。 Objective To evaluate the clinical application of 16 slice spiral computer tomagraphy for diagnosis and treatraent of pulmonary embolism. Mothods 30 cases with pulmonary embolism accepted 16 slice spiral computer tomagraphy enhanced scan. 2 cases accepted enhanced scan again after a week. Results 25 cases with pulmonary embolism 16SCT revealed normal. 5 cases were diagnosed pulmonary embolism.2 cases revealed that thrombus almost vanishied after Trombolytic treatment.2 cases revealed that symptom was almost totally resolved after Trombolytic treatment.1 cases died .Conclusion 16 slice spiral CT angiography is an accurate method for detection pulmonary embolism.
机构地区 大庆油田总医院
出处 《基层医学论坛》 2006年第5期443-444,F0003,共3页 The Medical Forum
关键词 体层摄影术 X线计算机 效果评价 肺栓塞 血栓溶解疗法 Thrombectomy Tomography X-ray Computed Evaluate effect Pulmonary embolism Trombolytic Therapy
  • 相关文献

参考文献5

二级参考文献10

  • 1[1]Millward SF, Peterson RA, Moher D, et al. LGM(Vena Tech) venacava filter: experience at a single institution[J]. J Vasc Interv Radiol,1994, 5(2): 351-356.
  • 2[2]Athanasoulis CA, Kaufman JA, Halpern EF, et al. Inferior vena cava filters: review of a 26-year single-center clinical experience[J]. Radiology, 2000, 216(1):54-66.
  • 3[3]David W, Gross WS, Colaiuta E, et al. Pulmonary embolus after vena cava filter placement[J]. Am Surg, 1999, 65(4): 341-346.
  • 4[4]Crochet DP, Stora O, Ferry D, et al. Vena Tech-LGM filter: long-term results of a prospective study[J]. Radiology, 1993, 188(3): 857-860.
  • 5[5]Poletti PA, Becker CD, Prina L, et al. Long-term results of the simon nitinol inferior vena cava filter[J]. Eur Radiol, 1998, 8(2): 289-294.
  • 6[6]Korbin CD, Reed RA, Taylor FC, et al. In vitro flow phantom analysis and clot-capturing ability of incompletely opened Vena Tech-LGM vena cava filters[J]. Cardiovasc Intervent Radiol, 1993, 16(1): 3-6.
  • 7[7]Millward SF, Marsh JI, Pon C, et al. Thrombus-trapping efficiency of the LGM(Vena Tech) and Titanium Greenfield filters in vivo[J]. J Vasc Interv Radiol, 1992, 3(1): 103-106.
  • 8[8]Crochet DP, Brunel P, Trogrlic S, et al. Long-term follow-up of Vena Tech-LGM filter: predictors and frequency of caval occlusion[J]. J Vasc Interv Radiol, 1999, 10(2 Pt 1): 137-142.
  • 9[9]Becker DM, Philbrick JT, Selby JB. Inferior vena cava filter: indications, safety, effectiveness[J]. Arch Intern Med, 1992, 152(10): 1985-1994.
  • 10[10]Helmberger T, Helmberger R, Holzknecht N, et al. Vena-cava-Filter Indikation, Komplikation, klinische Wertigkeit[J]. Radiology, 1998, 38(7): 614-623.

共引文献1898

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部