期刊文献+

城镇燃气铸铁管网改造方式的概述 被引量:6

Summary of the Reconstruction of Cast Iron Pipeline for Urban Fuel Gas
下载PDF
导出
摘要 当铸铁管输送的人工煤气被置换成天然气后,其承插接口和机械接口会因失去水分和芳香烃类物质而收缩,导致天然气泄漏。该文介绍了国内城市天然气置换时常用的几种对铸铁管进行改造的方法及其各自特点。 After manufactured town gas transmitted by cast iron pipeline is replaced by natural gas,fuel gas will leak out at the bell socket and mechanical connection because of shrinkage caused by water and aromatic hydrocarbon loss. The paper introduces some common ways of reconstruction of cast iron pipeline applied for urban natural gas change.
作者 彭雷
出处 《城市公用事业》 2006年第2期34-36,共3页 Public Utilities
  • 相关文献

参考文献2

二级参考文献7

  • 1[1]Charles de Winton. Emgas Pioneers Gas Conditioning by Humidification[J]. Gas World, 1975, (March): 141- 147.
  • 2[2]Gas Conditioning, SINO- FRENCH INTERNATINAL GAS TRAINING CENTRE, TONGJI University, 1990.
  • 3[3]P Merler, J Sauniere. Wetting Gas by Atomized Water[J]. Gas Journal, 1965, (Nov.10): 142-143.
  • 4[4]Fogging[J]. Gas World(Gas Transmission),1968, (Sep): 13-15.
  • 5[5]E W Pickering. Planning[J]. Gas World,1967, (Oct): 16-18.
  • 6冯良,杨庆泉,全惠君,高军,许张健,卢春明.青浦人工煤气转换为LPG混空气之燃气加湿技术[J].上海煤气,2001(1):8-12. 被引量:3
  • 7秦朝葵,张维,何琳.天然气加湿输送技术简介[J].煤气与热力,2001,21(3):250-252. 被引量:13