摘要
通过对电气安装工程电气设备现场交流耐压试验容量的计算,提出了针对不同容量的被试电气设备在现场开展交流耐压试验时试验仪器设备的选型方案,结合现场实际应用情况,阐述了现场大容量交流耐压设备的应用前景。
By calculating the HV AC withstand test of power installation equipment at site, puts forward the method for selecting the site AC HV withstand test instrument according to different type of samples, with reference of site application, states the perspectives of applying the AC HV testing instruments with larger capacities.
出处
《电气化铁道》
2006年第2期17-19,共3页
Electric Railway
关键词
绝缘耐压
试验
容量
设备
计算
选型
withstand voltage of insulation
test
capacity
equipment
calculate