摘要 传统的垃圾焚烧炉焚烧温度低,因产生大量二恶英而被新一代垃圾处理装置取代。等离子体垃圾处理炉的处理温度高达3000℃~30000℃,可将垃圾中包括二恶英在内的所有有机成分在几毫秒的时间内彻底分解,小分子产物进人二燃室高温燃尽。RITS设计完成的用于医疗垃圾处理的等离子体炉包括垃圾自动上料装置、等离子发生器系统、主炉、尾气处理系统及自动控制系统共5部分。相比INER,改进后的RITS等离子炉在节能、脱氮、降低炉墙厚度及提高启停速度等方面的性能有了更大地提高。 The problem of exhausting dioxins under low incineration temperature made traditional incinerator be replaced by newer waste disposal unit. Relatively, with the processing temperature of 3 000℃ -30 000℃, the thermal plasma system can disposal all kinds of waste and all the organic compounds including dioxins were decomposed into small molecule, which can be burned out in the secondary combustion chamber. The thermal plasma system used for the medical waste treatment, designed by RITS, consists of 5 parts: waste self-feeding unit, plasma generator system, main furnace, off-gas treatment system and automatic control system. Compared with INER's system, the improved RITS plasma system achieves more success in the way of energy conservation, denitrification, reducing brickwork thickness and improving the start-stop speed.
出处 《锅炉技术》 北大核心 2006年第1期63-66,共4页 Boiler Technology
关键词 热等离子体系统 医疗垃圾 改进 thermal plasma system medical waste improvement
  • 相关文献

参考文献5

  • 1Krystyna Cedzynska, Zbigniew Kolacinski. Michal izydorczyk and witold sroczynski[A]. 1999 International Ash utilization Symposium[C]. 1999.
  • 2N. Lapa, J. F. Santos Oliveira, S.L. Camacho, et al. An ecotoxic risk assessment of residue materials produced by the plasma pyrolysis/vitrification (PP/V) process [J]. Waste Management, 2002,22: 335-342.
  • 3Kjell E. Haugsten, Bengt Gustavson. Environmental properties of vitrified fly ash from hazardous and municipal waste incineration[J]. Waste Management, 2000, (20) : 167-176.
  • 4Chin-Ching Tzeng, Yung-Yen Kuo, Tsair-Fuh Huang, et al. Treatment of radioactive wastes by plasma incineration and vitrification for final disposal[J]. Journal of Hazardous Materials, 1998, 58:207-220.
  • 5J.P. Chu, I.J. Hwang, C.C. Tzeng, et al. Characterization of vitrified slag from mixed medical waste surrogates treated by a thermal plasma system[J]. Journal of Hazardous Materials, 1998, 58:179-194.

同被引文献101

引证文献9

二级引证文献70

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部