期刊文献+

质子弹性散射分析方法测量mylar膜上气溶胶样品的氢含量

PROTON ELASTIC SCATTERING ANALYSIS METHOD TO MEASURE HYDROGEN CONCENTRATION OF AEROSOL ON MYLAR FILM
下载PDF
导出
摘要 利用标准样品比较法质子弹性散射分析(PESA)对一组采集在mylar膜上的气溶胶样品氢含量进行了定量分析.在质子束能量2.5 MeV,散射角50°时,PESA测量5μm mylar膜上气溶胶中氢含量的探测限为0.26μg·cm^-2,几个样品氢含量的测量结果在1.9~12.7μg·cm^-2之间,大大高于探测限. The proton elastic scattering analysis (PESA) method is introduced, and the H concentration of 4 aerosol samples on mylar films is measured with PESA in the PIXE analysis chamber of GIC4117 tandem accelerator. With 2.5 MeV proton beam and 50 degree scattering angle, the detectable limit of PESA is 0. 26μg·cm^-2 for aerosol samples on 5μm mylar films. The PESA results show that the H concentration of these aerosol samples is from 1.9 to 12. 7 μg·cm^-2, much higher than the detectable limit of PESA. Key words
出处 《北京师范大学学报(自然科学版)》 CAS CSCD 北大核心 2006年第2期154-156,共3页 Journal of Beijing Normal University(Natural Science)
基金 国家自然科学基金资助项目(10275006)
关键词 质子弹性散射分析(PESA) 气溶胶 氢含量 proton elastic scattering analysis aerosol hydrogen concentration
  • 相关文献

参考文献10

  • 1Cohen D D,Bailey G M,Kondepudi R.Elemental analysis by PIXE and other IBA techniques and their application to source fingerprinting of fine particle pollution[J].Nuclear Instruments and Methods in Physics Research,1996,B109/110:218.
  • 2Cahill T A,Eldred R A,Kusko B H.The hydrogen sulfur correlation by PIXE plus PESA and aerosol source identification[J].Nuclear Instruments and Methods in Physics Research,1987,B22:296.
  • 3Malm W C,Sisler J F,Huffman D,et al.Spatial and seasonal trends in particle concentration and optical extinction in the United States[J].J Geophys Res,1994,99(D1):1347.
  • 4Nejedly Z,Campbell J L,Teesdale W J,et al.Comparison of multielemental analyses of aerosol samples by PIXE,PESA,EDXRF and IC[J].Nuclear Instruments and Methods in Physics Research,1995,B103:473.
  • 5Nejedly Z,Campbell J L,Teesdale W J,et al.PIXE and PESA aspects of the Guelph visibility and fine particulate monitoring program[J].Nuclear Instruments and Methods in Physics Research,1997,B132:489.
  • 6Voltr J,Kral J,Nejedly Z.PESA as a complementary tool to PIXE at CTU Prague[J].Nuclear Instruments and Methods in Physics Research,1999,B150:554.
  • 7Shutthanandan V,Thevuthasan S,Disselkamp R,et al.Development of PIXE,PESA and transmission ion microscopy capability to measure aerosol by size and time[J].Nuclear Instruments and Methods in Physics Research,2002,B189:284.
  • 8Bench G,Grant P G,Ueda D,et al.The use of STIM and PESA to measure profiles of aerosol mass and hydrogen content,respectively,across mylar rotating drums impactor samples[J].Aerosol Science and Technology,2002,36:642.
  • 9王广甫 朱光华 董平.2×1.7 MV串列加速器PIXE管道及其在气溶胶分析中的应用[J].过程工程学报,2002,(2):247-247.
  • 10朱唯干.背散射分析技术[M].北京:原子能出版社,1986.136.