期刊文献+

超声引导下颈部淋巴结细针穿刺细胞学检查的准确性 被引量:20

Accuracy of Ultrasound-guided Normal Linear Array Probe on Fine Needle Biopsy of Superficial Neck Lymph Nodes
下载PDF
导出
摘要 目的探讨利用超声普通线阵探头引导进行细针穿刺细胞学检查的准确性及定位技巧。方法对进行普通线阵探头引导细针穿刺细胞学检查并经活切或手术组织病理学检查的156例颈部肿大淋巴结的诊断结果进行分析。结果普通线阵探头引导细针穿刺细胞学检查一次穿刺成功率93%,对良、恶性病变的诊断准确率分别为96%、91%。结论超声普通线阵探头引导进行细针穿刺细胞学检查诊断准确率高,对于明确颈部肿大淋巴结性质有重要的应用价值。 Objective To study the accuracy and the locational skills of the fine needle biopsy via ultrasound- guided common linear array probe. Methods The fine needle biopsy guided with common linear array probe was carried out on 156 patients with swollen nodes of the neck who were also accepted subsequent local biopsy or surgical resection. The results acquired were compared with that of cytology and pathology. Results The first-time successful rate of fine needle biopsy guided with common linear array probe was 93%.The accurate rate in the diagnosis of, benign diseases and malignant diseases was 96% and 91% respectively. Conclusions Fine needle biopsy guided with common linear array probe possesses a good accuracy in judging the nature of diseases and is a valuable method in defining the quality of swollen nodes in the neck.
出处 《中国超声诊断杂志》 2006年第5期326-328,共3页 Chinese Journal of Ultrasound Diagnosis
关键词 普通超声线阵探头 细针活检 浅表颈部淋巴结 病理学检查 Common linear array transducer, Fine needle biopsy, Superficial neck lymph node.
  • 相关文献

参考文献4

二级参考文献22

  • 1Moore EH. Technical aspects of needle aspiration lung biopsy:a personal perspective. Radiology, 1998, 208:303-318.
  • 2Protopapas Z, Westcott JL. Transthoracic hilar and mediastinal biopsy. Radiol Clin North Am, 2000,38:281-291.
  • 3Screaton NJ, Flower CD. Percutaneous needle biopsy of the pleura. Radiol Clin North Am, 2000, 38:293-301.
  • 4Metintas M, Ozdemir N, Isiksoy S, et al. CT-guided pleural needle biopsy in the diagnosis of malignant mesothelioma. J Comput Assist Tomogr, 1995,19:370-374
  • 5Garcia Rio F, Diaz Lobato S, Pino JM, et al. Value of CT-guided fine needle aspiration in solitary pulmonary nodules with negative fiberoptic bronchoscopy. Acta Radiol, 1994,35:478-480.
  • 6Larscheid RC,Thorpe PE,Scott WJ. Percuteneous transthoracic needle aspiration biopsy:a comprehensive review of its current role in the diagnosis and treatment of lung tumors. Chest, 1998,114:704-709.
  • 7Tsukada H, Satou T, Iwashima A, et al. Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol, 2000,175:239-243.
  • 8Li H, Boiselle PM, Shepard JO, et al. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol, 1996,167:105-109.
  • 9Sheiman RG, Fey C, McNicholas M, et al. Possible causes of inconclusive results on CT-guided thoracic and abdominal core biopsies. AJR Am J Roentgenol, 1998,170:1603-1607.
  • 10Katada K,Kato R,Anno H,et al. Guidance with real-time CT fluoroscopy:early clinical experience. Radiology, 1996,200:851-856.