期刊文献+

自动测量心搏出量改进法定量评价偏心性二尖瓣反流

Quantitative assessment of eccentric mitral regurgitation by modified ACOM
下载PDF
导出
摘要 目的研究并证实自动心脏输出量测量法(ACOM)改进法定量评价二尖瓣偏心性反流。方法对19例患偏心性反流患者采用ACOM改进法,于收缩相对经二尖瓣反流瓣口的血流速度直接进行时间和空间双重积分,得到二尖瓣反流量,并将反流量作为评价参数,对患者的反流严重程度进行划分。最后,比较分析反流量与由实时三维彩色多普勒超声心动图测量得到的射流容积和反流狭径宽度之间的相关性。结果以反流量大小作为标准,3例患者被判定为轻度,10例患者被判定为中度,6例患者被判定为重度。ACOM改进法得到的反流量与射流容积(r=0.9371)和反流狭径宽度(r=0.8939)高度相关。结论ACOM改进法是对偏心性二尖瓣反流进行定量的有效方法。 Objective To investigate and validate a modified automatic cardiac output measurement (ACOM) method to quantify the eccentric mitral regurgitation (MR). Methods By directly integrating the mitral regurgitant jet in space and in time during the systole, 19 patients with eccentric MR were examined by the modified ACOM, and the severity of the 19 patients using RV as evaluation parameter was graded. Finally, the RV was compared with the jet volume (JV) and vena contracta width (VCW) obtained by the real time three-dimensional echocardiography (RT-3DE). Results Three patients were diagnosed as mild, 10 patients as moderate and 6 patients as severe using the RV as criterion. The RV obtained by modified ACOM correlated well with the reference data, JV (r=0. 9371) and VCW (r=0. 8939), respectively. Conclusion The modified ACOM is a feasible method for quantifying eccentric MR.
出处 《中国医学影像技术》 CSCD 北大核心 2006年第4期610-612,共3页 Chinese Journal of Medical Imaging Technology
基金 国家自然科学基金项目(60272060) 教育部博士点基金(20030610032) 教育部优秀青年教师项目(2003-355-2)。
关键词 自动心脏输出量测量法 二尖瓣闭锁不全 实时三维超声心动图 Automatic cardiac output measurement Mitral valve insufficiency Real-time three-dimensional echocardiography
  • 相关文献

参考文献10

  • 1Shiota T,Jones M,Teien D,et al.Color Doppler regurgitant jet area for evaluating eccentric mitral regurgitation:an animal study with quantified mitral regurgitation[J].J Am Coll Cardiol,1994,24(3):813-819.
  • 2Hozumi T,Yoshida K,Akasaka T,et al.Automated assessment of mitral regurgitant volume and regurgitant fraction by a newly developed digital color Doppler velocity profile integration method[J].Am J Cardiol,1997,80(10):1325-1330.
  • 3李德玉,赵树魁,尹立雪,汪天富,郑昌琼,尹光福.一种超声组织多普勒图像的定量分析新方法[J].航天医学与医学工程,2001,14(1):17-21. 被引量:10
  • 4Kim WY,Poulsen JK,Terp K,et al.A new Doppler method for quantification of volumetric flow:in vivo validation using color Doppler[J].J Am Coll Cardiol,1996,27(1):82-92.
  • 5Sun JP,Yang XS,Qin JX,et al.Quantification of mitral regurgitation by automated cardiac output measurement:experimental and clinical validation[J].J Am Coll Cardiol,1998,32(4):1074-1082.
  • 6张军,钱蕴秋,郭庆林.彩色多普勒过返流口宽度与射流参数评估二尖瓣返流的对照研究[J].中国医学影像技术,1998,14(5):319-321. 被引量:1
  • 7Zoghbi WA,Enriquez-Sarano M,Foster E,et al.Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography[J].J Am Soc Echocardiogr,2003,16(7):777-802.
  • 8袁莉,谢明星,王新房,吕清,卢晓芳,贺林,方凌云,张跃力,王瑶,蒲朝霞,刘夏天,邓斌华.实时三维彩色多普勒超声评价偏心性二尖瓣反流量的初步探讨[J].中华超声影像学杂志,2005,14(3):165-169. 被引量:10
  • 9De Simone R,Glombitza G,Vahl CF,et al.Three-dimensional color Doppler reconstruction of intracardiac blood flow in patients with different heart diseases[J].Am J Cardiol,2000,86(12):1343-1348.
  • 10Tsujino H,Jones M,Shiota T,et al.Estimation of the spatial mean and peak flow velocities using real-time 3D color Doppler echocardiography:in vitro and in vivo studies[J].Computers in Cardiology,1999,26(1):173-176.

二级参考文献18

  • 1Yin L X,J Am Coll Cardiol,1999年,33卷,3期,782页
  • 2Yin L X,Circulation,1998年,78卷,suppl期,1页
  • 3Utsunomiya T,Patel D, Doshi R,et al. Can signal intensity of the continuous wave Doppler regurgitant jet estimate severity of mitral regurgitation? Am Heart J, 1992,123:166-171.
  • 4Pu M,Vandervoort PM,Griffin BP, et al. Quantification of mitral regurgitation by the proximal convergence method using transesophageal echocardiography. Clinical validation of a geometric correction for proximal flow constraint. Circulation, 1995,92 :2169-2177.
  • 5Blumlein S,Bouchard A,Schiller NB,et al. Quantitation of mitral regurgitation by Doppler echocardiography. Circulation, 1986,74:306-314.
  • 6De Simone R,Glombitza G,Vahl CF,et al. Three-dimensional color Doppler: a clinical study in patients with mitral regurgitation. J Am Coll Cardiol, 1999,33: 1646-1654.
  • 7De Simone R, Glombitza G, Vahl CF, et al. Three-dimensional Doppler. Techniques and clinical applications. Eur Heart J, 1999,20 : 619-627.
  • 8Schluter M, Langenstein BA, Hanrath P, et al. Assessment of transesophageal pulsed Doppler echocardiography in the detection of mitral regurgitation. Circulation, 1982,66: 784-789.
  • 9Chao K, Moises VA, Shandas R, et al. Influence of the Coanda effect on color Doppler jet area and color encoding. In vitro studies using color Doppler flow mapping. Circulation, 1992,85: 333 341.
  • 10Enriquez-Sarano M, Dujardin KS, Tribouilloy CM, et al.Determinants of pulmonary venous flow reversal in mitral regurgitation and its usefulness in determining the severity of regurgitation. Am J Cardiol, 1999,83: 535 541.

共引文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部