期刊文献+

三维对比增强MR血管成像在头颈部的临床应用 被引量:4

Three Dimensional Contrast Enhanced MR Angiography:Its Applications in Head and Neck
下载PDF
导出
摘要 目的:探讨三维对比增强MR血管成像(3DCE-MRA)在头颈部的临床应用价值。材料和方法:应用3D小角度激发快速梯度回波序列,对76例临床疑头颈部血管疾病患者进行3DCE-MRA检查。结果:76例3DCE-MRA均获成功,3DCE-MRA图像明确显示了病变部位及范围。结论:3DCE-MRA快速、准确,有利于头颈部血管疾病的诊断和治疗。 To evaluate the application of three dimensional contrast - enhanced MR angiography(3D CE - MRA) in head and neck. Materials and Methods: 3D CE - MRA was performed in 76 cases who were suspicious of vessels disease, three dimensional fast low angle single shot sequence was used. 3D reconstruction techniques, including MIP and MPR, were adopted, and the images thus obtained were compared with each other.Results: 3D CE - MRA was successful in 76 cases, and the position and extension of the lesions could be revealed on 3D MRA images. Either MIP or MPR has its advantage in revealing the lesions of the vessels. Conclusion: 3D CE - MRA is a noninvasive and favorable method of depicting vessels, which can provide more information for clinic.
出处 《中国医学计算机成像杂志》 CSCD 2006年第2期88-91,共4页 Chinese Computed Medical Imaging
  • 相关文献

参考文献9

  • 1陆建平,刘崎,何新红,王飞,王莉,金爱国,曾浩,范明霞.三维对比剂增强MR血管成像对颈部动脉病变的诊断价值[J].中华放射学杂志,2004,38(1):76-81. 被引量:81
  • 2Lee VS,Martin DJ,Krinsky GA,et al.Gadiolinium-enhanced MR angiography:artifacts and piffalls.A JR,2000,175:197~200.
  • 3Poon E,Yucel EK,Pagan-Marin H,et al.Lliac artery stenosis measurements:comparison of two-flight and three-dimensional dynamic gadolinium enhanced MR angiography.A JR,1997,167:1137~1144.
  • 4Foo TKF,Saranathan M,Prince MR,et al.Automatic detection of bolus arrival time and initiation of data acquisition in fast three-dimensional gadolinium-enhanced MR angiography.Radiology,1997,203:275~280.
  • 5Catalano C,Laghi A,Pediconi F,et al.Magnetic resonance angiography with contrast media in the study of carotid arteries.Radiol Med,2001,102:54~59.
  • 6Nederkoorn PJ,Mali WP,Eikelboom BC,et al.preoperative diagnosis of carotid artery stenosis:accuracy of noninvensive testing.Stroke,2002,33:2003~2008.
  • 7Sundgren PC,Sunden P,Lindgren A,et al.Carotid artery stenosis:contrast enhanced MR angiography with two different scan times compared with digital subtraction angiography.Neuradiology,2002,44:592~599.
  • 8Cosottini M,Calabrese R,Puglioli M,et al.Contrast-enhanced three-dimensional MR angiography of neck vessels:does dephasing effect alter diagnostic accuracy? Eur Radiol,2003,13:571~581.
  • 9刘崎,陆建平,王飞,王莉,田建明,金爱国,曾浩.三维动态增强MR血管造影对颅内动脉瘤的诊断价值[J].中华放射学杂志,2003,27(3):238-242. 被引量:34

二级参考文献11

  • 1Hop JW, Rinkel GJE, Algra A, et al. Case fatality rates and functional outcome after subarachnoid hemorrhage: a systematic review. Stroke, 1997, 28:660-664.
  • 2Berteloot D, Leclerc X, Leys D, et al. Cerebral angiopraphy : a study of complications in 450 consecutive procedures. J Radiol, 1999, 80:843-848.
  • 3White PM, Teasdale EM, Wardlaw JM, et al. Intracranial aneurysms: CT angiography and MR angiography for detection-prospective blinded comparison in a large patient cohort. Radiology, 2001, 219:739-749.
  • 4Farb RI, McGregor C, Kim JK, et al. Intracranial arteriovenous malformations: real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography-initial assessment. Radiology, 2001, 220:244-251.
  • 5Nakajima Y, Yoshimine T, Yoshida H, et al. Computerized tomography angiography of ruptured cerebral aneurysms: factors affecting time to maximum contrast concentration. J Neurosurg, 1998,88:663-669.
  • 6Huston J, Fain SB, Riederer SJ, et al. Carotid arteries: maximizing arterial to venous contrast in fluoroscopically triggered contrast-enhanced MR angiography with elliptic centric view ordering. Radiology, 1999, 211:265-273.
  • 7Saitoh H, Hayakawa K, Nishimura K, et al. Rerupture of cerebral aneurysms during angiography. AJNR, 1995, 16:539-542.
  • 8Watanabe Z, Kikuchi Y, Izaki K, et al. The usefulness of 3D MR angiopraphy in surgery for ruptured cerebral aneurysms. Surg Neurol, 2001,55:359-364.
  • 9M. Cosottini,R. Calabrese,M. Puglioli,V. Zampa,M. Michelassi,S. Ortori,L. Murri,C. Bartolozzi. Contrast-enhanced three-dimensional MR angiography of neck vessels: does dephasing effect alter diagnostic accuracy?[J] 2003,European Radiology(3):571~581
  • 10P. Sundgren,P. Sundén,A. Lindgren,J. Lanke,S. Holt?s,E.-M. Larsson. Carotid artery stenosis: contrast-enhanced MR angiography with two different scan times compared with digital subtraction angiography[J] 2002,Neuroradiology(7):592~599

共引文献113

同被引文献41

引证文献4

二级引证文献55

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部