摘要 目的:探讨动态心电图监测室上性早搏ST段下移对冠心病的诊断意义和价值。方法:对158例临床诊断为冠心病的患者分为观察组及对照组136例进行Holter检查。结果:观察组室上性早搏的STx、STx-S阳性变化与对照组之间差异有统计学意义(P<0.01),诊断冠心病的敏感性分别是63.9%和62.0%。结论:Holter检出室上性早搏的ST段水平下移或下斜型下移≥0.1mv或上斜型下移≥0.2mv;STx-S>0.5mv用于诊断冠心病有一定临床辅助价值。 Objective:To investigate the significance and value of ST segment shifting downward of supraventricular premature beat to the diagnosis of coronary heart disease(CHD) in dynamic eleetrocardiogram(ECG).Methods:158 patients with CHD diagnosed by clinic and 136 normal controls were examined by Holter. Results:The positive changes of STx and STx-s in the CHD group showed significant difference from thos in the control group (P〈0.01). The diagnostic sensitivity of STx and STx-s for CHD was 63.9% and 62.0% respectively. Conclusion:The extents of ST segment shifting downward of supraventrieular prmature beat in horizontal type or inferio-oblique type≥0.1 my or supra-oblique≥0.2 mv;STx〉0.5 my detected by Holier have a certain clinical value in the assisted diagnosis of CHD.
作者 郑学良
出处 《现代医药卫生》 2006年第10期1449-1450,共2页 Journal of Modern Medicine & Health
关键词 动态心电图 室上性早搏 冠心病 ST段下移 Dynamic ECG Supraventrieular premature beat Coronary heart disease
  • 相关文献

参考文献4

  • 1张天滋.心电图信息学[M].北京:北京科技出版社,1998.574.
  • 2张娟.24小时动态心电图冠心病的诊断价值[J].临床心电学杂志,1998,1(12):88-88.
  • 3Warner RA,Hill NE,Lynch T.Usefulness of abnormalities of repolarization in the electrocardiographic diagnosis of healed myocardial infarction[J].J Electrocardiol,1988,21 (Suppl):S93.
  • 4刘泊坤.室上性早搏ST段压低对冠心病的诊断价值[J].心电学杂志,1998,11(2):90-90.

相关作者