期刊文献+

EAST电源系统补偿及滤波装置的监测与保护系统的研制 被引量:1

Development of a Monitoring and Protecting System for the Reactive Compensation and Harmonic Suppression Device of EAST Power Supply System
下载PDF
导出
摘要 介绍了EAST电源系统的谐波抑制和无功补偿的设计方案,及其控制保护与监测系统的研制,包括滤波装置的PLC控制系统、装置继电保护的设计、滤波补偿装置工作状态的监测及供电电网电能质量分析等。实验充分验证了该系统的可行性。 This paper introduces a solution of reactive compensation and harmonic suppression for high power supply system,and a monitoring & proteeting system is developed, which includes the PLC system in the filtering device, the relay protection of the device, work state monitoring of the filtering compensation deviee, and the power quality analysis of the power supply network. The exoeriments show its feasibility,
出处 《电测与仪表》 北大核心 2006年第4期27-29,57,共4页 Electrical Measurement & Instrumentation
关键词 谐波抑制 无功补偿 继电保护 电能质量 harmonic suppression reactive compensation relay protection power quality
  • 相关文献

参考文献6

  • 1LiuZZ,TaoJ.The design of power supply system of HT-7U superconductive Tokamak[J].Fusion Engineering and Design,2001,58-59:75-782.
  • 2Wakileh George J.电力系统谐波-基本原理、分析方法和滤波器设计[M].北京机械工业出版社,2003.
  • 3谢书勇.在电网中运行的真空断路器操作过电压真空断路器操作过电压及其保护论文集(摘录)[C].中国电器工业协会高压开关分会,1999:1-4.
  • 4张万忠,等.电器与PLC控制技术[M].北京化学工业出版社,2004.
  • 5贺家李.电力系统继电保护[M].北京:水利电力出版社,1994.
  • 6国际电工委员会.IEC 60870-5-103继电保护设备信息接口配套标准[M].中国电力出版社,1999.