100-200MW空冷汽轮发电机的通风与温升计算 被引量:7

Ventilation and Temperature Calculation of a 100~200 MW Air-Cooled Turbine Generator
下载PDF
导出
摘要 简要介绍了大型空冷汽轮发电机冷却系统,阐明了定子铁芯及线圈温升计算方法和转子线圈直线部分温升计算方法,分析了该发电机通风冷却系统主要结构特点。该发电机运行于125 MW,13.8 kV时的温升与通风计算和试验结果表明:该发电机通风损耗小,温度分布均匀,冷却效果好。 The cooling system of large air-cooled turbine generators is briefly described, together with a presentation of methods for calculating the temperature of the stator' s core and coils, and accompanied by an analysis of the main structural features of the cooling system. Both calculated and test determined temperatures show that in case of the generator operating at 125 MW, 13.8 kV, ventilation loss is low, temperature distribution even and cooling effect satisfactory.
出处 《发电设备》 2006年第3期193-195,共3页 Power Equipment
关键词 能源与动力工程 发电机 空气冷却 定子径向风道 间接冷却 副槽径向通风 直接冷却 energy and power engineering generator air-cooling stator' s radial air duct indirect-cooling subsidiary trough's axial air duct direct-cooling
  • 相关文献

参考文献2

  • 1上海汽轮发电机有限公司.定子铁芯及线圈温升计算程序使用说明书[Z].1997.
  • 2上海汽轮发电机有限公司.转子线圈温升计算程序使用说明书[Z].1995.