直接酶联免疫吸附法检测猪血清中G型免疫球蛋白(IgG),最小检测量为10ng,最适检测范围纯IgG为10~60ng,猪血清IgG为10~40ng。酶标抗体最适稀释度为1/3500。酶标板内与酶标板间平行测定变异系数均小于5%。
This paper studied the method of measuring Immunoglobulin G in porcine serum by Direct Enzyme-Linked Immunoserbent Assay. ELISA's smallest measurement limit was 10 ng. The best measurement ranges were 10~60 ng for pure IgG and 10~40 ng for porcine serum IgG. The best titer of Peroxidase Conjugate Antibody was 1/3500. Variation coefficient of parallel determination in same and different boards were all less than 5 % .