摘要 实验研究了具有电磁光栅驱动装置的顺序等离子体光谱仪的波长定位精度,讨论了影响波长定位精度的因素。结果表明,其波长定位精度与机械驱动光栅光谱仪相同,但扫描速度远高于后者。 The wavelength poeitioning accuracy of sequential ICP spectiometer with electromagnetically driving grating is in-vestigatea experimentally. Influencing factors are discussed. The experimemal resulls indicate that the electromag-netically driving grating has the saroe wavelength positioning accuracy as the mechanically driving grating,but the scanning speed of the former is much higher than the later.
作者 辛仁轩
出处 《分析仪器》 CAS 1996年第3期12-14,共3页 Analytical Instrumentation
  • 相关文献

参考文献1

  • 1辛仁轩,1984年

同被引文献29

  • 1赵朝辉.ICP-AES法测定镨钕混合物中的钐及多重谱线拟合法的应用[J].矿产综合利用,2007(4):47-49. 被引量:7
  • 2J. A. C. Broekaert,N. Jakubowski.New plasma discharges for atomic spectrometry[J]. Analytical and Bioanalytical Chemistry . 2007 (8)
  • 3Almagro B M,Alfonso,Hidalgoa M,et al.Behaviour ofa flow focusing pneumatic nebulizer with high total dis-solved solids solution on radially-and axially-viewed in-ductively coupled plasma atomic emission spectrometry. Journal of Analytical Atomic Spectrometry . 2006
  • 4Acon B W,McLean J A,Montaser A.A Large Bore-Di-rect Injection High Efficiency Nebulizer for Inductively Coupled Plasma Spectrometry. Analytical Chemistry . 2000
  • 5Almagro B,Gan A M,Canals A.Preliminary character-ization and fundamental properties of aerosols generated by a flow focusing pneumatic nebulizer. Anal.At.Spectrom . 2004
  • 6Larrea M T,Zald B,Farinet J C,et al.Matrix effect of aluminium,calcium and magnesium in axially viewing inductively coupled plasma atomic emission spectrome-try. Journal of Analytical Atomic Spectrometry,J.Anal.At.Spectrom . 2008
  • 7Dudnikov S Y,Kartasheva M A,Moshkovich.Spectro-analytical characteristics of low-flow,water-cooled torch inductively coupled plasma. ICP Information Newlettler . 1995
  • 8Nimalasirz K,Solva D,Guevetmont.Direct powder in-troduction inductively coupled plasma atomic emission spectrometry with a photodiode array spectrometer. Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy . 1991
  • 9Pilon M J,Denton M B,Schleicher R G.Evaluation of a New Array Detector Atomic Emission Spectrometer for Inductively Coupled Plasma Atomic Emission Spectros-copy. Applied Spectroscopy . 1990
  • 10Barnard T W,Crockett M I,Ivaldi J C,et al.Solid-state Detector for ICP-OES. Analytical Chemistry . 2003

引证文献2

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部