期刊文献+

某大型泵站机组振动原因分析及水力改善措施 被引量:3

Analysis on vibration of pumping unit and improvement of hydraulic condition for a large pumping station
下载PDF
导出
摘要 某大型泵站建成运行后机组出现间隙性振动,通过分析认为,泵体结构存在局部缺陷,由此对进水池水流流态要求较高;另一方面,原经过水工模型试验优化的进水池结构在实施时发生了变更,使得流道内水流不甚均匀。最后从改善水流流态着手提出了消振措施。 The intermittent vibration occurs in a large-scale pumping station during the initial operation just after the completion of the project. Through the analysis concerned, it is found that the structure of the pump body has some local defects, and then the higher requirement for the flow pattern in the water intake pond is necessary. On the other hand, the structure of the intake pone originally optimized through the hydraulic model test concerned is changed during construction, which makes the flow pattern of the flow therein is not so uniform. Under this condition, a vibration damping measure is put forward based on the improvement of the flow pattern.
作者 赖翼峰
出处 《水利水电技术》 CSCD 北大核心 2006年第4期57-60,共4页 Water Resources and Hydropower Engineering
关键词 泵站 机组振动 原因分析 水流流态 消振措施 pumping station unit vibration analysis flow pattern vibration damping
  • 相关文献

参考文献4

  • 1GB/T50265-97.泵站设计规范[S].[S].,..
  • 2国家电力公司电力规划设计总院.火力发电厂循环水泵房进水流道及其布置设计技术规定[R].1999.
  • 3广东省水利水电科学研究所.某抽水泵站引水渠及进水池水工模型试验研究[R].1999.
  • 4广东省水利水电科学研究院.某抽水泵站引水渠、前池及进水流道模型试验研究[R].2003.