摘要
主要针对马钢制氧机净循环水系统设备、管道的腐蚀情况,结合系统工艺状况,阐述了净循环水系统清洗预膜过程和效果分析。
In the light of the corrosion state of plants and pipes of the clean circulation water system for air separators of Maanshan Iron & Steel Co., Ltd. and combining the process state of the system, the cleaning pre-membrane procedure of the clean circulation water system and the effect are expounded. The control methods for cleaning pre-membrane of the system under abnormal state are discussed.
出处
《冶金动力》
2006年第1期28-30,共3页
Metallurgical Power
关键词
停车清洗
剥离
预膜
腐蚀速率
cleaning during shutdown
stripping
pre-membrane
corrosion rate