期刊文献+

Initial Stability Study of Calcium Phosphate Coated Dental Implants

Initial Stability Study of Calcium Phosphate Coated Dental Implants
下载PDF
导出
摘要 Thin film of biodegradable calcium phosphate coated on threaded commercially pure titanium ( cp- Ti ) dental implants has been investigated as one of alternatives to eliminate the problem of the long- term instability of plasma sprayed HA coated implants. In order to compare in-vivo bone-to-implant response behavior among as-machined, HA coated and CMP coated groups, each group was implanted into New Zealand white mature male rabbits for 2 and 6 weeks, and then in-vivo biological behavior was examined in terms of H&E staining. Initial stability and removable torques of implants were compared among three groups. Measured removable torque of CMP coated specimen at 6 weeks after inplantation was significantly higher than that of non-coated group, but slightly lower than that of HA coated group, without any inflammatory response at the surrounding of the implants. The initial stability ( ISQ value ; implant stability quotient ) of CMP coated specimen at 2 weeks after implantation was slightly lower than that of HA coated group and significantly higher than that of non-coated group. However, after 6 weeks, ISQ value of CMP coated group was slightly higher than that of HA coated group and significantly higher than that of non-coated group. Thin film of biodegradable calcium phosphate coated on threaded commercially pure titanium ( cp- Ti ) dental implants has been investigated as one of alternatives to eliminate the problem of the long- term instability of plasma sprayed HA coated implants. In order to compare in-vivo bone-to-implant response behavior among as-machined, HA coated and CMP coated groups, each group was implanted into New Zealand white mature male rabbits for 2 and 6 weeks, and then in-vivo biological behavior was examined in terms of H&E staining. Initial stability and removable torques of implants were compared among three groups. Measured removable torque of CMP coated specimen at 6 weeks after inplantation was significantly higher than that of non-coated group, but slightly lower than that of HA coated group, without any inflammatory response at the surrounding of the implants. The initial stability ( ISQ value ; implant stability quotient ) of CMP coated specimen at 2 weeks after implantation was slightly lower than that of HA coated group and significantly higher than that of non-coated group. However, after 6 weeks, ISQ value of CMP coated group was slightly higher than that of HA coated group and significantly higher than that of non-coated group.
出处 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2005年第B12期246-248,共3页 武汉理工大学学报(材料科学英文版)
基金 SupportedbyaGrantfromYeungnamUniversityin2005andaGrant(No.R012005000108030)fromtheBasicResearchProgramoftheKoreaScience&EngineeringFoundation
关键词 calcium metaphosphate initial stability RFA ISQ value OSSEOINTEGRATION calcium metaphosphate initial stability RFA ISQ value osseointegration
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部