期刊文献+

彩色多普勒超声检测妊娠高血压综合征眼动脉血流量 被引量:1

Volume of OA Blood Flow in Prgnancy-induced Hypertension Syndrome Determined by Color Doppler Ultrasound
下载PDF
导出
摘要 目的:探讨妊娠高血压综合征(PIH)患者眼动脉(OA)血流量变化。材料与方法:应用彩色多普勒超声(CDUS)检测41例PIH患者81条OA和36例正常妊娠(NP)者72条OA的血流速度、血管内径,计算每条动脉的血流量。结果:PIH组OA平均血流速度、平均血管内径及血流量与NP组比较具有显著性差异(P<0.01,P<0.05,P<0.01)。结论:PIH患者OA血流量较NP者增多。 Purpose: To explore volume changes of OA in patients with pregnancy- induced Hypertension Syndrome (PHI), Matedals and Methods: Velocity of blood flow and vessels ID were determined by Color Doppler Ultrasound (CDUS) in both 81 stripes of OA in PIH patients and 72 stripes of OA in NP, and the voltune of blood flow in each artery was calculated. Results: There were significant differences in OA mean velocity of blood flow, mean vessels ID and volume of blood flow in PIH group compared to NP group (P〈 0.01, 〈 0.05, 〈 0.01, respectively). Condusion: The volume of OA blood flow in PIH patients is higher than that of NP patients.
作者 陈坤赞
出处 《现代医用影像学》 2006年第1期35-36,共2页 Modern Medical Imageology
关键词 妊娠高血压综合征 眼动脉 血流量 彩色多普勒超声 Pregnancy- induced hypertension Ophthalmic artery Volume of blood flow Color Doppler Ultrasound
  • 相关文献

参考文献4

二级参考文献2

共引文献19

同被引文献26

  • 1Carry DM, Delles C, Dominiczak AF. Novel biomarkers for predicting preeclampsia [ J ]. Trends Cardiovasc Med, 2008,18 (5) : 186-194.
  • 2Corretti MC, Anderson TJ, Benjamin EJ, et al. Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery : a report of the International Brachial Artery Reactivity Task Force [ J ]. J Am Coil Cardiol,2002,39 (2) : 257-265.
  • 3Rassaf T, Heiss C, Hendgen-Cotta U, et al. Plasma nitrite reserve and endothelial function in the human forearm cir-culation [ J ]. Free Radic Biol Med ,2006,41 (2) :295-301.
  • 4Savvidou MD, Hingorani AD, Tsikas D, et al. Endothelial dysfunction and raised plasma concentrations of asymmet- ric dimethylarginine in pregnant women who subsequently develop pre-eclampsia [ J ]. Lancet, 2003,361 ( 9368 ) : 1511-1517.
  • 5Yamashina A, Tomiyama H, Takeda K, et al. Validity, re- producibility, and clinical significance of noninvasive bra- chial-ankle pulse wave velocity measurement[ J]. Hyper- tens Res, 2002,25 (3) : 359-364.
  • 6Mohamed M, Larmie ET, Singh HJ, et al. Tissue kal- likrein and kininogen levels in fetoplacental tissues from normotensive pregnant women and women with pregnan- cy-induced hypertension[ J ]. Eur J Obstet Gynecol Re- prod Biol,2007,134 ( 1 ) :15-19.
  • 7Bamfo JE, Kametas NA, Nicolaides KH, et al. Maternal left ventricular diastolic and systolic long-axis function during normal pregnancy [ J ]. Eur J Echocardiogr, 2007, 8(5) :360-368.
  • 8Vazquez Blanco M, Roisinblit J, Grosso O, et al. Left ven- tricular function impairment in pregnancy-induced hyper- tension[ J ]. Am J Hypertens ,2001,14( 3 ) :271-275.
  • 9McDicken WN,Sutherland GR, Moran CM,et al. Colour Doppler velocity imaging of the myocardium [ J ]. Ultra- sound Med Biol, 1992,18 ( 6-7 ) :651-654.
  • 10Steinhard J, Heinig J, Schmitz R, et al. Tissue Doppler imaging of the fetal heart-a new parametric ultrasound technique in prenatal medicine [ J ]. Ultraschall Med, 2007,28 (6) :578-583.

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部