简要介绍氧气分析报警仪的工作原理,重点叙述了在氧化铝厂镓回收生产中FP—524C型分析仪的安装、标定和调试方法。
This article is to introduce the ing, adjustment and calibration of FP-524C refinery. operating principle of hydrogen analyzer and the mounthydrogen analyzer used for gallium recovery in alumina
出处
《自动化与仪器仪表》
2006年第3期73-75,78,共4页
Automation & Instrumentation
关键词
镓回收
气体分析
磁化编程棒
氢气
标定
Gallium recovery
Gas analysis
Magnetized programming stick
Hydrogenl Calibration