摘要
通过事故分析,提出对导叶开度限制及弹簧力要求并相应协联关系、主令控制器、监控控制都要设置得当,相应配合,否则易突发事故影响机组正常运行。
By the accident analysis, it is known there shall be a corresponding on-cam relationship between wicket gate opening limitation and requirement of spring force. The major command controller and monitoring control should be properly set. Otherwise fault is likely to occur and affects the normal operation of the power-generating unit.
出处
《电站系统工程》
北大核心
2006年第3期49-50,共2页
Power System Engineering
关键词
导水机构
开度
行程
限制
翻转
distributor
opening
stroke
limitation
turning over