摘要 本文介绍了2005年1月24日~28日在重庆市江津白沙镇进行的室内热环境问卷调查与测试,通过对室内通风情况、设备使用情况以及其它方面的调查和室内热环境总体满意度几个方面的调查分析,得到了夏热冬冷地区小城镇室内热环境的主观评价指标,并将此与《夏热冬冷地区居住建筑节能设计标准》(JGJ134-2001)和《重庆市居住建筑节能设计标准》(DB50/5009-1999)中的设计值比较,提出了适合当地实际情况的室内热环境设计值。 This text has introduced the in-door thermal environmental questionnaire investigation carried on in the town ofBai Sha of the city in Jiangjin on the 24th - 28th of January, 2005, and by analysis of these four respects, the survey of indoor ventilation situation, the operating position of the equipments, other respects investigation and overall satisfaction of in-door thermal environment, have received the subjective evaluation index of the in-door thermal environment of small town in hot summer and cold winter zone. Through compare with the design value in energy-conserving design standard of the building in hot summer and cold winter zone (JGJ 134-2001) and energy-conserving design standard of the building in Chongqing (DB50/5009-1999), proposed the thermal environment design value in the room suitable for the local actual conditions.
出处 《重庆建筑》 2006年第5期19-23,共5页 Chongqing Architecture
关键词 室内环境 问卷调查 in-door environment questionnaire investigation