期刊文献+

Correlation between Post-LASIK Starburst Symptom and Ocular Wavefront Aberrations 被引量:2

Correlation between Post-LASIK Starburst Symptom and Ocular Wavefront Aberrations
下载PDF
导出
摘要 Monochromatic aberrations in post laser in-situ keratomileusis (LASIK) eyes are measured. The data are categorized into reference group and starburst group according to the visual symptoms. Statistic analysis has been made to find the correlation between the ocular wavefront aberrations and the starburst symptom. The rms aberrations of the 3rd and 4th orders for the starburst group are significantly larger than those for the reference group. The starburst symptom shows a strong correlation with vertical coma, total coma, spherical aberrations. For 3-mm pupil size and 5.8-mm pupil size, the modulation transfer function (MTF) of the starburst group are lower than those of the reference group, but their visual acuities are close. MTF and PSF analyses are made for two groups, and the results are consistent with the statistical analysis, which means the difference between the two groups is mainly due to the third- and fourth-order Zernike aberrations. Monochromatic aberrations in post laser in-situ keratomileusis (LASIK) eyes are measured. The data are categorized into reference group and starburst group according to the visual symptoms. Statistic analysis has been made to find the correlation between the ocular wavefront aberrations and the starburst symptom. The rms aberrations of the 3rd and 4th orders for the starburst group are significantly larger than those for the reference group. The starburst symptom shows a strong correlation with vertical coma, total coma, spherical aberrations. For 3-mm pupil size and 5.8-mm pupil size, the modulation transfer function (MTF) of the starburst group are lower than those of the reference group, but their visual acuities are close. MTF and PSF analyses are made for two groups, and the results are consistent with the statistical analysis, which means the difference between the two groups is mainly due to the third- and fourth-order Zernike aberrations.
出处 《Chinese Physics Letters》 SCIE CAS CSCD 2006年第6期1498-1500,共3页 中国物理快报(英文版)
基金 Supported by the National Natural Science Foundation of China under Grant No 60438030, and the Key Research Foundation of Scientific and Technical Committee of Tianjin City of China under Grant No 033183711.
关键词 LASER PHOTOREFRACTIVE KERATECTOMY QUALITY EYE SURGERY FILTERS MYOPIA LASER PHOTOREFRACTIVE KERATECTOMY QUALITY EYE SURGERY FILTERS MYOPIA
  • 相关文献

参考文献18

  • 1Al-Kaff A S 1997 J. Refract. Surg. 13 459.
  • 2Hersh P S et al 1997 Ophthalmology 104 1535.
  • 3Waring G O 1997 J. Refract. Surg. 13 213.
  • 4Diamond S 1995 Aviat. Space. Environ. Med. 66 690.
  • 5Oshika T et al 2004 J. Cataract. Refract. Surg. 30 1929.
  • 6Mierdel P et al 1999 Graefes. Arch Clin. Exp. Ophthalmol. 237 725.
  • 7Moreno B E et al 2001 Invest. Ophthalmol. Vis. Sci. 42 1396.
  • 8Liang J and Williams D R 1997 J. Opt. Soc. Am. A 14 2873.
  • 9Williams D R, Brainard D, MacHahon M and Navarro T 1994 J. Opt. Soc. Am. A 11 3123.
  • 10Zhang L S, Zhang L, Zhang C P et al 2004 Chin. Phys. Lett. 21 2517.

同被引文献2

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部