摘要
研究了APDC/MIBK萃取体系分离、富集高纯稀土氧化钐中的痕量铁,用石墨炉原子吸收光谱法测定,详细探讨了萃取条件和测定条件等。对氧化钐实际样品测定,其相对标准偏差低于7%,加标回收率9l%-104%,方法简单,准确和实用。
In this paper,the meassuring condition and the extracting condition are studied.Trace Iron in highly pure samaria is successfully determined.The relative standard deviations are less than 7%.The recovery is 91% to 104%.The method is simple,accurate and practical.
出处
《冶金分析》
CAS
CSCD
北大核心
1996年第5期31-32,22,共3页
Metallurgical Analysis
关键词
氧化钐
铁
石墨炉
原子吸收光谱法
Samaria,Iron,Extraction,Graphite furnace atomic absorption spectrometry