期刊文献+

不锈钢换热器板片泄漏原因分析 被引量:7

LEAK ANALYSIS ON STAINLESS STEEL RADIATOR BOARD
下载PDF
导出
摘要 316不锈钢换热器板片在使用中发生泄漏。对失效件进行了金相检验、腐蚀产物的成分分析,以及应力状态分析,对腐蚀起主要作用的氯离子的来源,以及氯离子在应力腐蚀过程中循环作用的机理作了探讨。结果表明,该换热器板片泄漏为应力腐蚀所致。 The leak reason of 316 stainless steel radiator board was stress corrosion according to the results of metallographic examnation, chemical compositon ananlysis of the corrosive product and stress state analysis of failure specimen. Stress corrosion mechanisms was discussed. The source of Cl^- responsible for the corrosion mainly and cyclical reaction mechanisms of Cl^- during the stress corrosion process of stainless steel were studied in detail.
作者 王荣
机构地区 上海材料研究所
出处 《理化检验(物理分册)》 CAS 2006年第5期255-257,共3页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 应力腐蚀 孪晶奥氏体 穿晶 滑移 Stress-corrosion Twin austenite Transgranular Slip
  • 相关文献

参考文献3

  • 1任赞颂,张静江.钢铁金相图谱[M].上海:上海科学技术文献出版社,2003.864.
  • 2John Sedriks A.不锈钢的腐蚀[M].北京:机械工业出版社,1986.
  • 3张静江.不锈钢管应力腐蚀开裂失效分析[A].第三界全国失效分析会议论文集[C].上海:上海材料研究所出版,1988.

共引文献5

同被引文献18

引证文献7

二级引证文献24