期刊文献+

重肝肝移植手术应用微孔多聚糖止血球的止血效果(附18例临床报告) 被引量:3

Hemostatic effect of microporous polysaccharide hemospheres in liver transplantation of patients with serious hepatitis:a report of 18 cases
下载PDF
导出
出处 《第二军医大学学报》 CAS CSCD 北大核心 2006年第5期575-575,共1页 Academic Journal of Second Military Medical University
  • 相关文献

参考文献3

  • 1Ereth MH,Henderson JL,Schrader LM,et al.Efficacy of microporous polysaccharide hemospheres on liver punch biopsies in porcine model[J].Anesthesiology,2003,99:A153.
  • 2Murat FJ,Ereth MH,Dong Y,et al.Evaluation of microporous polysaccharide hemispheres as a novel hemostatic agent in open partial nephrectomy:favorable experimental results in the porcine model[J].J Urol,2004,172:1119-1122.
  • 3Tan SR,Tope WD.Effectiveness of microporous polysaccharide hemispheres for achieving hemostasis in mohs micrographic surgery[J].Dermatol Surg,2004,30:908-914.

同被引文献53

  • 1王为民,何远翔,黄海林,王强,查玮.多微孔多聚糖止血球控制门静脉高压手术创面活动性出血的疗效[J].第二军医大学学报,2005,26(11):1311-1312. 被引量:6
  • 2沈晨阳,张小明,李伟,焦洋,蒋京军.术中止血材料——Arista^(TM)在血管外科中的应用[J].中华普通外科杂志,2006,21(7):532-533. 被引量:9
  • 3谢肇,许建中,周强,谭祖键.Arista微孔多聚糖止血球在胸腰椎前路减压术中的临床应用[J].中华创伤杂志,2006,22(12):894-896. 被引量:5
  • 4冯少清,陈绍宗,司徒镇强,李学拥,李跃军,李望舟.止血用ZSM-5沸石的生物相容性评价[J].医疗卫生装备,2007,28(1):22-25. 被引量:4
  • 5Ho J, Hruza G. Hydrophilic polymers with potassium salt and micro- porous polysaccharides for use as hemostatic agents. Dermatol Surg, 2007, 33: 1430-1433.
  • 6Murat FJ, Le CQ, Ereth MH, et al. Evaluation of microporous polysaccharide hemospheres for parenchymal hemostasis during lao paroscopic partial nephrectomy in the porcine model. JSLS, 2006, 10: 302-306.
  • 7Murat FJ, Ereth MH, Dong Y, et al. Evaluation of microporous polysaccharide hemospheres as a novel hemostatic agent in open partial nephrectomy: favorable experimental results in the porcine model. JUrol, 2004, 172: 1119-1122.
  • 8Tan SR, Tope WD. Effectiveness of mieroporous polysaeeharide hemospheres for achieving hemostasis in mobs micmgraphic surgery. Dermatol Surg, 2004, 30: 908-914.
  • 9Gross JB. Estimating allowable blood loss: corrected for dilution. Anesthesiology, 1983, 58: 277-280.
  • 10Everts PA, Devilee RJ, Brown Mahoney C, et al. Platelet gel and fibrin sealant reduce allogeneie blood transfusions in total knee arthroplasty. Acta Anaesthesiol Scand, 2006, 50: 593-599.

引证文献3

二级引证文献4