期刊文献+

主动脉机械瓣膜置换术后低强度抗凝研究 被引量:7

Research on clinical supervise of anti-coagulation therapy after replacement prosthetic mechanical aortic valve
原文传递
导出
摘要 目的 研究广东地区人工机械主动脉瓣膜置换术后行低强度抗凝的可行性及安全强度。方法 对120例主动脉机械瓣膜置换的患者,按国际标准化比值(INR)进行抗凝监测,其范围控制在1.5~1.8。并对患者应用华法林抗凝治疗的临床效果进行回顾分析。结果 120例患者术后抗凝并发症明显低于文献报道,无栓塞病例,少许轻微出血事件亦无需特殊处理,临床效果良好。结论 主动脉瓣人工机械瓣膜置换术后。在我国南方地区行较低强度抗凝治疗(INR=1.5~1.8),具有较高的安全性和可行性。 Objective To evaluate the possibility and safety bounds of low intense anti-coagulation therapy after replacement prosthetic mechanical aortic valve. Methods 120 cases with replacement prosthetic mechanical aortic valve were studied. According to the international normalized ratio, INR of all the patients were controlled in 1.5 - 1.8. The clinical anticoagulation effect were analyzed to provide or reduce the occurrence of anticoagulation related complications. Results The rates of complications in 120 patients were lower than those reported in the foreign literature. Conclusion It is acceptable to practice low intense anti-coagulatlon therapy after replacement prosthetic of aortic mechanical valve in the south of china. And it is safety and feasible to control INR between 1.5 - 1.8 after the operation.
出处 《中国基层医药》 CAS 2006年第4期594-595,共2页 Chinese Journal of Primary Medicine and Pharmacy
关键词 主动脉瓣置换术 心脏瓣膜 人工 华法林 国际标准化比 Mechanical aortic valve replacement Heart valve prosthesis Warfarin International normalized ratio
  • 相关文献

参考文献9

  • 1Stein PD,Alpert JS,Copeland J,et al.Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves.Chest,1992,102Suppl:445-455.
  • 2Hirsh J,Dalen JE,Deykin D,et al.mechanism of a clinical effectiveness and optimal therapeutic range of oral anticoagulants.Chest,1992,102(Suppl 4):312-314.
  • 3杜心灵,张凯伦,胡志伟,蓝鸿钧,金咏梅.人工机械瓣膜替换术后凝血功能改变及合理抗凝强度的研究[J].中华实验外科杂志,1999,16(1):62-63. 被引量:16
  • 4Horstkotte D,Schulte H,Bircks W,et al.Unexpected findings concerning thromboembolic complications and anticoagulation after complete 10 year follow up of patients with St.Jude medical prostheses.J Heart Valve Dis,1993,2:291-293.
  • 5Katircioglu SF,Yamak B,Ulus AT,et al.Mitral valve replacement with St.Jude medical prosthesis and low dose anticoagulation in patients aged over 50 years.J Heart Valve Dis,1998,7:455-458.
  • 6Kanalka Y,Tanemoto K,Murakami T,et al.Thromboembolic and bleeding complications in patients treated with oral anticoagulant therapy after mechanical heart valve prostheses implantation.Kyobu Geka,2000,53:754-757.
  • 7Rosendaal FR,Van der Meer FJM,Cannegicter SC.Management of anticoagulant therapy the Dutch experience.J thromb Thrombolysis,1996,2:265-269.
  • 8Stien PD,Alpert JS,Bussey HI,et al.Antithrombotic therapy in patients with mechanical and biological heart valves.Chest,2001,119Suppl:220-227.
  • 9Pruefer D,Dahm M,Dohmen G,et al.Intensity of oral anticoagulation after implantation of St-jude medical mitral or multitude valve replacement:lessons leared from GELIA(GELIA5).Eur Heart J,2001,(Suppl Q):39-43.

共引文献15

同被引文献79

引证文献7

二级引证文献80

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部